9. ELECTRICAL CONNECTIONS

The electrical connections must be made by expert, qualified personnel.
ATTENTION! ALWAYS RESPECT THE LOCAL SAFETY REGULATIONS.
Always switch off the mains power supply before working on the electrical or
mechanical part of the system. Wait for the warning lights on the control panel to go
out before opening the appliance. The capacitor of the direct current intermediate
circuit remains charged with dangerously high voltage even after the mains power has
been turned off.
Only firmly cabled mains connections are admissible. The appliance must be earthed
(IEC 536 class 1, NEC and other applicable standards).
THE SYSTEM MUST BE CORRECTLY AND SAFELY EARTHED!
It is advised to install a correctly dimensioned differential switch to protect the system,
type: class A with adjustable leakage current, selective.
The automatic differential switch must be marked with the following symbols:
The circulator does not require any external motor protection.
Ensure that the supply voltage and frequency are the same as the values indicated on the electrical
data plate of the circulator.