4 Putting into operation
4 Putting into operation
4.1 Equipping the torch
1
Torch body
2
Collet
Abb. 1
Torches ABITIG
EN - 8
DANGER
Risk of injury due to unexpected start-up
The following instructions must be adhered to for the entire duration of
maintenance, servicing, mounting, dismounting and repair work:
• Switch off the power source.
• Close the gas supply.
• Close off the compressed air supply.
• Disconnect all electrical connections.
• Switch off the entire welding system.
CAUTION
Risk of injury
Through-hole or puncture caused by sharpened electrode.
• Do not reach into the danger zone.
• Wear protective gloves.
Equip the torch neck according to one of the following figures:
Step 2 is omitted for the torches ABITIG
1
2
Step 1
3
Torch cap
4
Tungsten electrode
®
Little 24G, 24W, 9, 17, 25
®
Little 24G, 24W.
3
4
Step 2
Step 3
5
®
ABITIG
5
Gas nozzle
Little