Contacting Fluke - Fluke 1AC I VoltAlert Hoja De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Safety Compliance: Meets IEC 61010-1:2001, UL 61010-1 (2nd ed.), CAN/
CSA-C22.2 No. 61010-1-04, and ISA-82.02.01
EMC Compliance: Meets IEC 61326-1:2006
Operating: 90 V ac to 1000 V ac
Temperature: Operating: -10 to 50 °C Storage: -10 to 50 °C
Humidity: 0 % to 95 % (0 to 30 °C), 0 % to 75 % (30 to 40 °C), 0 % to 45 % (40
to 55 °C)
Altitude: 2000 m (CAT IV 1000 V)
Pollution Degree: 2
Cleaning
Clean with damp cloth.
Operating Instructions
The product is always on and ready to use, subject to battery and Tester
condition.
Checking Battery and Tester
Push the Battery Check Button. If the tip glows, the batteries are good and the
Tester is operational. If the tip does not glow, replace batteries with two AAA
(LR3) batteries. If the Tester still does not function, have it serviced.
Checking for AC Voltage
Placing the tip of the Tester near an ac voltage (within the specified range of the
Tester) produces a steady glow at the tip.

Contacting Fluke

Technical Support USA: 1-800-44-FLUKE (1-800-443-5853)
Calibration/Repair USA: 1-888-99-FLUKE (1-888-993-5853)
Canada: 1-800-36-FLUKE (1-800-363-5853)
Anywhere in the world: +1-425-446-5500
Or, visit Fluke's website at www.fluke.com.
To register your product, visit http://register.fluke.com.
To view, print, or download the latest manual supplement, visit
http://us.fluke.com/usen/support/manuals.
LIMITED WARRANTY AND LIMITATION OF LIABILITY
This Fluke product will be free from defects in material and workmanship for two
years from the date of purchase. This warranty does not cover fuses, disposable
batteries, or damage from accident, neglect, misuse, alteration, contamination,
or abnormal conditions of operation or handling. Resellers are not authorized
to extend any other warranty on Fluke's behalf. To obtain service during the
warranty period, contact your nearest Fluke authorized service center to obtain
return authorization information, then send the product to that Service Center
with a description of the problem.
THIS WARRANTY IS YOUR ONLY REMEDY. NO OTHER WARRANTIES,
SUCH AS FITNESS FOR A PARTICULAR PURPOSE, ARE EXPRESSED OR
IMPLIED. FLUKE IS NOT LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL
OR CONSEQUENTIAL DAMAGES OR LOSSES, ARISING FROM ANY CAUSE
OR THEORY. Since some states or countries do not allow the exclusion or
limitation of an implied warranty or of incidental or consequential damages, this
limitation of liability may not apply to you.
Fluke Corporation
P.O. Box 9090
Everett, WA 98206-9090
U.S.A.
11/99
Fluke Europe B.V.
P.O. Box 1186
5602 BD Eindhoven
The Netherlands

Publicidad

Tabla de contenido
loading

Tabla de contenido