Beretta QUADRA GREEN 25 R.S.I. Manual De Instalacion Y Uso página 24

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

QUADRA GREEN 25 R.S.I.
4.2 Switching off
Temporary switch-off
In case of absence for short periods of time, set the mode selector (fig.
31) to
(OFF).
In this way (leaving the electricity and fuel supplies enabled), the boiler is
protected by the following systems:
Anti-frost device: when the temperature of the water in the boiler falls
below 5°C, the circulator and, if necessary, the burner are activated at mini-
mum output levels to bring the water temperature back to the values for
safety (35°C). During the anti-frost cycle, the symbol
on the digital monitor.
Circulator anti-blocking function: an operation cycle is activated every
24 hours.
DHW Antifreeze (only when connected to an external storage tank with
probe): the function is activated if the temperature measured by the storage
tank probe drops below 5° C. A heat request is generated in this phase with
the ignition of the burner at minimum power, which is maintained until the
water temperature reaches 55° C. During the anti-frost cycle, the symbol
(fig. 35) appears on the digital monitor.
Switching off for long periods
In case of absence for long periods of time, set the mode selector (fig. 31) to
(OFF). Turn the main system switch OFF. Close the fuel and water taps
of the heating and domestic hot water system. In this case, anti-frost device
is deactivated: drain the systems, in case of risk of frost.
4.3 Light signals and faults
To restore operation (deactivate alarms):
Faults A 01-02-03
Position the function selector to
the required position
(summer mode) or
If the reset attempts do not reactivate the boiler, contact the Technical As-
sistance Centre.
Fault A04
In addition to the fault code, the digital display shows the symbol
Check the pressure value indicated by the water gauge:
if it is less than 0.3 bar, position the function selector to
the filling tap until the pressure reaches a value between 1 and 1.5 bar.
Then position the mode selector to the desired position
(winter). The boiler will perform one purge cycle lasting approxi-
mately 2 minutes. If pressure drops are frequent, request the intervention of
the Technical Assistance Service.
BOILER STATUS
Off status (OFF)
Stand-by
ACF alarm lockout module
ACF electronics fault alarm
Fumes exhaust - air intake obstruction alarm
Limit thermostat alarm
Tacho fan alarm
Water pressure switch alarm
NTC domestic water fault (only when con-
nected to an external storage tank with probe)
NTC heating outlet fault
Heating outlet probe overtemperature
Outlet/return line probe differential alarm
NTC heating return line fault
Heating return line probe overtemperature
Outlet/return line probe differential alarm
Cleaning the primary heat exchanger
NTC flue gases fault
Flue gases probe overtemperature
False flame
Low temperature system thermostat alarm
Temporary pending ignition
Water pressure switch intervention
24
(fig. 35) appears
(OFF), wait 5-6 seconds then set it to
(winter mode).
(OFF) and adjust
(summer) or
DISPLAY
OFF
-
on
A01
flashing 0.5 on/
A02
0.5 off
on
A03
on
A04
flashing 0.5 on/
A06
0.5 off
on
A07
on
A08
flashing 0.5 on/
0.5 off
A09
on
flashing 0.2 on/
A11
0.2 off
on
A77
Fault A06 - A07 - A08
Contact the Technical Assistance Centre.
Fault A09 with fixed red LED lit
Position the function selector to
required position (summer mode) or (winter mode).
If the reset attempts do not reactivate the boiler, request the intervention of
the Technical Assistance Service.
Fault A09 with flashing red and green LEDs
The boiler is equipped with an auto-diagnostic system which, based on the
total number of hours in certain operating conditions, can signal the need
to clean the primary exchanger (alarm code 09 with flashing red and green
LEDs and flue gas meter >2,500).
Once the cleaning operation has been completed, using the special kit sup-
plied as an accessory, the total hour meter will need to be reset to zero as
follows:
- switch off the power supply
- remove the housing
- loosen the fixing screw then turn the instrument panel
- loosen the fixing screws on the cover (F) to access the terminal board (fig. 16)
- while the boiler is powered up, using a small screwdriver included, press
the CO button (fig. 26) for at least 4 seconds, to check the meter has
been reset, power down then power up the boiler; the meter reading is
shown on the monitor after the "-C-" sign.
Live electrical parts.
Note: the meter resetting procedure should be carried out after each in-
depth cleaning of the primary exchanger or if this latter is replaced. To
check the status of the total hour meter, multiply the reading by 100 (e.g.
reading of 18 = 1800 total hours; reading of 1 = 100 total hours).
The boiler continues to operate normally even when the alarm is activated.
Fault A77
This is an automatic-reset fault, if the boiler does not restart, contact the
Technical Assistance Centre.
Flashing yellow LED
.
Combustion analysis in progress.
RED LED
YELLOW LED
(OFF), wait 5-6 seconds then set it to the
TYPES OF
GREEN LED
ALARMS
flashing 0.5 on/
None
3.5 off
flashing 0.5 on/
Signal
3.5 off
Definitive lockout
Definitive lockout
Definitive lockout
on
Definitive lockout
flashing 0.5 on/
Signal
0.5 off
Temporary stop
Temporary then
definitive
Definitive lockout
Temporary stop
Temporary then
definitive
Definitive lockout
Signal
flashing 0.5 on/
0.5 off
Temporary stop
Definitive lockout
Temporary stop
Temporary stop
flashing 0.5 on/
Temporary stop
0.5 off
flashing 0.5 on/
Temporary stop
0.5 off