Transducer, Installation - Balluff BTL5-A Serie Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

BTL5-A/C/E/G1_-M/U_ _ _ _-T-_S 32
Micropulse Linear Transducer - Rod Style
3
Installation (cont.)
calibration
device
Fig. 3-2: BTL5...T-3S 32, transducer dimensions
Important Installation Notes:
The contact surface of the trans-
ducer must be completely con-
tacted by the mounting surface.
The O-ring supplied must make a
perfect pressure seal, i.e. the bevel
for the O-ring must be configured
exactly as shown in ➥ ➥ ➥ ➥ ➥ Fig. 3-3.
To achieve secure mounting, use
the proper nut for the mounting
thread. When tightening the nut, do
3.2

Transducer, installation

The smallest permissible distance
between magnet ring and mounting
surface of the BTL housing is
shown in ➥ ➥ ➥ ➥ ➥ Fig. 3-2.
The BTL transducer is supplied with
an M30×1.5 mounting thread. Seal-
ing is accomplished with the O-ring
(supplied) at the flange contact sur-
face.
4
english
Factory setting
nominal length
= measuring range
magnet ring
mounting
surface
not exceed a tightening torque of
150 Nm.
For horizontal mounting of trans-
ducer with stroke lengths greater
than 500 mm, the pressure tube
should be supported or attached at
its end.
When installing in a hydraulic cylin-
der, do not allow the magnet ring to
rub against the pressure tube. The
bore diameter in the piston and
Bevel for O-ring 27 × 2.5
Fig. 3-3: Threaded hole for installing BTL with O-ring
damping zone
(unusable area)
Permissible radial off-
set magnet ring to rod:
+1.5 mm
calibration
device
cylinder rod should be at least
27 mm.
When attaching the transducer to
magnetizable materials, appro-
priate measures must be taken to
protect against magnetic disturb-
ances, ➥ ➥ ➥ ➥ ➥ Fig. 3-1.
Note the recommended distance
of the transducer and cylinder from
strong, external magnetic fields.

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Btl5-с serieBtl5-e serieBtl5-g1 serie

Tabla de contenido