3
Installation (cont.)
3.3

Magnet ring, installation

Each transducer requires a magnet,
which must be ordered separately.
➥ ➥ ➥ ➥ ➥ Fig. 3-4
We recommend that magnet rings
be installed in or against non-mag-
netizable material. ➥ ➥ ➥ ➥ ➥ Fig. 3-1
Fig. 3-4: Magnet ring (order separately)
4

Wiring

Important wiring note:
The system and the con-
trol cabinet must be at the
same ground potential.
To ensure electromagnetic com-
patibility (EMC), which Balluff
verifies by the CE Marking, the
following points must be strictly
observed.
BTL transducer and controller
must be connected using
shielded cable.
Shield: Copper-stranded mesh,
80 % coverage.
not used
0 V
not used
0...10 V
GND
+24 V
Transducer
BTL5-A10-
...3S 32
Fig. 4-1: BTL5-A10...T-3S 32 with controller, wiring example
When routing the cable between
the transducer, controller and
power supply, avoid proximity to
high voltage lines to prevent noise
coupling. Especially critical is in-
ductive noise caused by AC har-
monics (e.g. from phase-control
devices), against which the cable
shield provides only limited protec-
tion.
BTL-P-1028-15R
The shield in the BKS connector
( ➥ ➥ ➥ ➥ ➥ Fig. 4-3) must be connected to
the connector housing; see in-
structions included with the con-
nector.
The cable shield must be grounded
on the controller side (connected
with the protection ground).
Refer to table 4-1 for wiring as-
signments. Connections on the
control side depend on the output
type.
YE
GY
PK
GN
BU
BN
Controller with
analog input
Length of signal transmission max.
20 m; Ø 6 to 8 mm. Longer lengths
may be used if construction, shield-
ing and routing are such that exter-
nal noise fields will have no effect on
signal integrity.
BKS connections,
view of solder side of
socket body
for BKS-S 32M-00
or BKS-S 33M-00
Fig. 4-2: BKS pin assignments,
connector to BTL
right-angle BKS-S 33M-00
No. 99-5672-78-08 ( Binder)
right-angle BKS-S 33M-00
No. 99-5672-78-08 (Binder part no.)
straignt BKS-S 32M-00
No. 99-5672-19-08 (Binder part no.)
Fig. 4-3: Connectors (optional)