BTL5-A/C/E/G1_-M/U_ _ _ _-T-_S 32
Micropulse Linear Transducer - Rod Style
Contents
1
Safety Advisory ..................... 2
1.1 Proper application ................. 2
1.2 Qualified personnel ............... 2
1.3 Use and inspection ................ 2
1.4 Scope ..................................... 2
2
characteristics ...................... 3
2.1 Characteristics ...................... 3
2.2 Function ................................. 3
3
Installation ............................ 3
3.1 Installation options ................ 3
4
Wiring .................................... 5
5
Start-up ................................. 6
5.1 Check connections ............... 6
5.3 Check output values .............. 6
5.4 Check functionality ............... 6
5.5 Fault conditions ..................... 6
6
Setup and calibration ........... 6
6.1 Selecting the calibration
procedure ............................... 7
6.2 Teach-in ................................. 7
6.3 Adjustment ............................. 7
6.4 Reset ...................................... 7
6.5 Online-setting ........................ 7
7
Teach-in mode ...................... 8
8
Manual adjust mode ............ 9
9
(Reset) ................................. 10
10
Online-setting mode .......... 11
11
Technical Data .................... 12
ambient ................................ 12
11.3 Outputs ................................ 12
11.6 Magnet ring .......................... 12
12
product label) ..................... 12
The following patents have been
granted in connection with this
product:
US Patent 5 923 164
Apparatus and Method for Auto-
matically Tuning the Gain of an
Amplifier
2
english
1
Safety Advisory
Read this manual before installing
and operating the Micropulse Trans-
ducer.
1.1
Proper application
The BTL5 Micropulse transducer is
intended to be installed in a ma-
chine or system. Together with a
controller (PLC) it comprises a posi-
tion measuring system and may
only be used for this purpose.
Unauthorized modifications and
non-permitted usage will result in
the loss of warranty and liability
claims.
1.2
Qualified personnel
This guide is intended for special-
ized personnel who will perform the
installation and setup of the system.
1.3
Use and inspection
Observe the relevant safety regula-
tions when using this positioning
The CE Mark verifies
that our products meet
the requirements of
EC Directive
89/336/EEC (EMC Directive)
and the EMC Law. Testing in our
EMC Laboratory, which is accred-
ited by DATech for Testing Electro-
magnetic Compatibility, has con-
firmed that Balluff products meet
the EMC requirements of the fol-
lowing Generic Standards:
EN 50081-2 (emission)
EN 61000-6-2 (noise immunity)
system. In particular measures
must be implemented to ensure
that any defect in the positioning
system cannot result in equipment
damage or personal injury. This
includes the installation of addi-
tional safety limit switches, E-Off
switches and observance of the
permissible ambient conditions.
1.4
Scope
This guide applies to the model
BTL5-A/C/E/G1...T... Micropulse
transducer.
An overview of the various models
can be found in section 12 Versions
(indicated on product label) on
page 12.
Note: Special versions (indicated
by the designation -SA_ _ _ in the
part number) may have other
technical data (e.g. for calibration,
connection or dimensions).
Emission tests:
RF Emission
EN 55011
Group 1, Class A
Noise immunity tests:
Static electricity (ESD)
EN 61000-4-2
Severity level 3
Electromagnetic fields (RFI)
EN 61000-4-3
Severity level 3
Fast transients (Burst)
EN 61000-4-4
Severity level 3
Surge
EN 61000-4-5
Severity level 2
Line-induced noise induced by
high-frequency fields
EN 61000-4-6
Severity level 3
Magnetic fields
EN 61000-4-8
Severity level 4