ADJUSTING THE MICROSWITCHES
DIP 1 CHECKING THE ROTATION DIRECTION OF THE
MOTOR (ON) (POINT C)
DIP 2 TIMING (ON) (POINT D)
OPERATING MICROSWITCH
DIP 3 Pausing time before automatic closing in normal
and pedestrian mode (ON)
DIP 4 Jogging radio receiver (OFF) - automatic (ON)
DIP 5 Single impulse command (K BUTT) jogging (OFF) - automatic
(ON)
DIP 6 Photocells always active (OFF) - Photocells active only on
closure (ON)
DIP 7 Encoder for the K PLUS operators (ON - operated)
DIP 8 Pre-blinking (ON) - Normal blinking (OFF)
DIP 9 Deceleration (ON) - MUST BE IN OFF POSITION -
DIP 10 Electronic brake (ON-operated)
DIP 11 Gradual start (ON- operated)
DIP 12 230V Motor (OFF) 120V (ON)
TORQUE - ELECTRONIC TORQUE REGULATOR
The torque is regulated by rotating the Trimmer TORQUE, varying the
output voltage of motor ends,(when rotated clockwise, more torque Is
transmitted to the motor).
Such torque Is automatically Included 2 seconds after the start of every
operating cycle.
This allows the motor to have the maximum pickup when it starts.
LOW SPEED - SPEED ADJUSTMENT DURING DECELERATION
WITH SUPER 3600 IS DISABLED
ELECTRONIC BRAKE (suggested operation)
If DIP 10 is ON, the system shall brake once the total opening or closing
have been carried out, so to avoid the inertia that would damage the gear
In the event of an Impact against the mechanical stops.
GRADUAL START (suggested operation)
If DIP 11 is ON, a gradual movement is enabled at every operation start.
This function is not active after the safety device detects an obstacle.
LED SIGNALS
DL1 photocells contact (NC)
DL2 stop contact (NC)
DL3 opening limit switch contact (NC)
DL4 closing limit switch contact (NC)
DL5 programming operated
DL6 gate on opening "OPEN" (green)
DL7 gate on closure "CLOSE" (red)
DL8 manual release safety device (NC)
DL9 Checking the encoder operation (only for K PLUS)
- C -
CHECKING THE ROTATION DIRECTION OF THE
MOTOR
This control is carried out to facilitate the installation of the system or any
possible future control.
1 - After you have ensured the correct positioning of the limit switch
plates (Fig.7), manually move the gate to half open position;
2 - Put DIP 1 in the ON mode => The LED DL5 starts blinking;
3 - Press the PROG button and hold it (the gate now is controlled in a
dead man mode: open, stop close stop open-etc...) => THE RED LED
DL7 "CLOSE" comes on and the gate starts closing (if it does not
close, invert the wires of the motor V and W) until it reaches the limit
switch of the close position (if the gate and motor do not stop, release
the PROG button and invert the position of the cables LSO and LSC
in the J9 connector);
4 - Press the PROG button and hold it => THE GREEN LED DL6
"OPEN" comes on and the gate opens until it reaches the limit
switch for opening position;
5 - After 2 sec. and within 10 sec. of continuous work, both in closing or
opening, the electronic clutch intervenes automatically. Adjust the
force of the clutch by turning the appropriate trimmer "TORQUE".
6 - At the end of the control, and of the trimmers' adjustements,
position DIP1 on mode OFF. The LED DL5 turns off, signalling you
exit from the control.
NB: The photocells are not active during this control.
- D -
TIMING
NB: DIP7 SHALL BE ON MODE OFF!!
The programming can be carried out regardless of the gate position.
1 - Put DIP 2 in the ON mode => the LED DL5 emits short blinkings.
2 - Push the button PROG. => the gate closes and opens automatically
2 seconds after It closed. When the opening cycle Is terminated, It
stops. Wait as long as you want the gate to remain open (excluded
by DIP3 OFF).
3 - Push the button PROG. to command the gate closing (also the pause
time count before the automatic closing stops - max. 5 minutes).
4 - The gate stops as the closing cam is reached.
5 - WHEN THE TIME PROGRAMMING IS COMPLETED, POSITION
DIP 2 ON MODE OFF.
If the INVERTER card is connected to the SUPER 2200 with the KS, the
card automatically controls its slowing-down on approaching and you can
also control the operator speed (read the Instructions enclosed to the
INVERTER card).
O
PERATION OF THE OPERATING ACCESSORIES
OPENING BUTTON (with timer function)
When the gate is standstill, the button operates the opening mode. If you
push this button when the gate is on closure, It opens again.
TIMER FUNCTION
This function is useful In the rush hours, when vehicle traffic is slow (e.g.
entry/exit of workers, emergencies In residential or parking areas and,
temporary, for removals).
APPLICATIONS
By connecting a switch and/or a daily/weekly timer (in place or in parallel
with the opening button N.O. "COM-OPEN"), it is possible to open the
automation or to keep It open, as long as the switch is on or the timer is
activated.
When the automation is open, all operating functions are inhibited.
If the automatic closing Is started, by releasing the switch or at the time
set before, the automation immediately closes; if not, you need to
operate a command.
CLOSING BUTTON (COM-CLOSE)
When the gate Is standstill, It operates the closing.
JOGGING OPERATION BUTTON (COM-K BUTTON)
If DIP5 is OFF => It cyclically commands open-stop-close-stop-open-etc.
If DIP5 is ON => It opens the gate when this Is closed. If It Is operated
while the gate Is opening, It has no effect. If It Is
operated when the gate is open, it closes the gate and,
If It Is operated while the gate Is closing, It opens the
gate again.