Programming
Cycle Segment Charts
Display
FIL 1, FIL 2, FIL 3, FIL 4, or FIL 5
dRIN or SRIN
00 or 02 to 15
HFIL, CFIL, or bFIL Select "HFIL" (hot fill), "CFIL" (cold fill), or "bFIL" (warm fill)**
LOLE or HILE
SUP0–SUP7
00°F, 75°F–200°F
00°C, 25°C–93°C
SPIn (flashed for one second)
tInE (flashed for one second)
00 or 30 to 120
*This is displayed only if spray rinse is enabled in the SETUP options.
**These steps are skipped if spray rinse is enabled in the SETUP options and "SRIN" is selected for
the segment.
†Supply 4 and Supply 7 are available only if Supply 4 is enabled in the SETUP options.
‡This is displayed only if auxiliary heat is enabled in the SETUP options.
28
(Continued)
Segments 3–7 (Fills 1–5)
Use the Up or Down key to change. Press the Start key to enter or advance.
Select rinse method: "dRIN" (dilution rinse), or "SRIN" (spray rinse)*
Select segment time: 02 to 15 minutes (00 to skip segment)
Select fill level: "LOLE" (low), or "HILE" (high) water level**
Select supply 0–7 (0 for no supply)**†
Select temperature: 75 to 200°F or 25 to 93°C (00 for no heat)**‡
Select time for spin: 30 to 120 seconds (00 for no spin)
Instructions
F232087