When connecting the machine, pay attention that the valve trigger 1 (see fig. 3) is not actuated.
Blow out the pneumatic hose bevor connecting the machine. Never connect a pneumatic hose
being under pressure (see safety instructions for prevention of hazards caused by compressed air).
First connect the machine and then connect the compressed air supply.
Prior to starting the machine put the reverse slide for rotation direction left and right into the correct
position.
For example, if you want to loosen a screw and the rotation direction is adjusted to a position for
screwing in, this can lead to violent uncontrolled movement of the pneumatic impact wrench.
Setting the rotation direction
The rotation direction is set with the reverse slide 2 (see fig. 4).
Actuate the reverse slide only when the pneumatic impact wrench is switched off.
Rotation direction right: For screwing-in of screws and nuts turn the reverse slide clockwise.
Rotation direction left: For unscrewing of screws and nuts turn the reverse slide anticlockwise.
Rotation direction right
Put the power socket wrench solidly and correctly on the screw head or the nut and start the
pneumatic impact wrench (see fig. 5).
26
STARTUP
Fig.3
Fig.4
Start and stop
Fig.5 Press or release