CPX-FVDA-P2
Electric characteristic values
Max. switching frequency of the output
channels
Max. voltage drop per output channel with
permanent load
Wire break detection (CH0, CH1, CH2)
Max. cable length (CH1, CH2)
Max. load capacity to FE
Max. load capacity P-M
Max. load inductivity
Fuse protection (short circuit)
Max. test pulse duration
Max. voltage drop during test pulse
Tab. 8:
Electric characteristic values
Fig. 6
Maximum permissible load inductivity at the output channels
54
CPX-FVDA-P2
[Hz]
1
[V]
0.6
Parameterisable,
detection threshold I
[m]
200
[nF]
400
[μF]
22
[mH]
1000 at 150 mA, 100 at 600 mA;
characteristic curve Fig. 6
Integrated electronic fuse
[μs]
300
[V]
6
approx. 50 mA
L
Festo CPX-FVDA-P2-Z6 1209NH English