9 ORDERING SPARE PARTS
Type of fault
No power/No arc
The overheating protection
trips frequently.
9
ORDERING SPARE PARTS
CAUTION!
Repair and electrical work should be performed by an authorised ESAB service
technician. Use only ESAB original spare and wear parts.
The EMP 215ic is designed and tested in accordance with international standards IEC-/EN
60974-1, IEC-/EN 60974-5, IEC-/EN 60974-7, IEC-/EN 60974-10, IEC-/EN 60974-12 and
IEC-/EN 60974-13. It is the obligation of the authorized service centre carrying out the
service or repair work to ensure that the product still conforms to the aforementioned
standards.
The spare parts list is published in a separate document that can be downloaded from the
Internet:
www.esab.com
0463 408 001
Corrective action
•
Check that the input power supply switch is turned on.
•
Check if a temperature fault is shown on display.
•
Check if system breaker is tripped.
•
Check that the input power, welding and return cables are
correctly connected.
•
Check that the correct current value is set.
•
Check the input power supply fuses.
•
Make sure that you are not exceeding the recommended
duty cycle for the weld current you are using.
See section "Duty cycle" in the OPERATION chapter.
•
Make sure the air inlets or outlets are not clogged.