Electrical Specifications; Grounding Instructions - Campbell Hausfeld HL4330 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

specifications
OVERVIEW OF YOUR PUMP
Breather/
Oil Fill
Sight Glass/
Oil Drain
Figure 2

ELECTRICAL SPECIFICATIONS

In the event of a malfunction or breakdown, grounding provides a path of least resistance for electrical current
to reduce the risk of electric shock. This compressor is equipped with an electric cord having an equipment-
grounding conductor and a grounding plug, as shown. The plug must be plugged into a matching outlet that is
properly installed and grounded in accordance with all local codes and ordinances.
Improper connection of the equipment-grounding conductor can result in a risk of electric shock. The conductor
with insulation having an outer surface that is green with or without yellow stripes is the equipment-grounding
conductor. If repair or replacement of the electric cord or plug is necessary, do not connect the equipment-
grounding conductor to a live terminal.
If the grounding instructions are not completely understood, or if you are in doubt as to whether the compressor is
properly grounded check with a qualified electrician or service personnel.

GROUNDING INSTRUCTIONS

1. This product is for use on a nominal 120 v circuit. It must be grounded. In the event of an electric short circuit,
grounding reduces the risk of electrical shock by providing an escape wire for the electric current. Unit is equipped
with a cord that has a grounding prong. It will fit one of the common outlet types shown in Figure 3. If plug will not
fit in the desired outlet, have the plug or the outlet replaced by a qualified electrician.
2. Always check with a qualified electrician or serviceman if the grounding instructions are not completely
understood, or if in doubt as to whether the product is properly grounded. Do not modify the plug provided; if it will
not fit the outlet, have the proper outlet installed by a qualified electrician.
3. Use only a 3-wire extension cord that has a 3-blade grounding plug, and a 3-slot receptacle that accepts the
plug on the product. Make sure your extension cord is not damaged. When using an extension cord, be sure to
use one heavy enough to carry the current your product draws. For lengths less than 25ft. 16-3 AWG extension
cords shall be used. An undersized cord results in a drop in the voltage and loss of power and overheating.
4. Use of an extension cord may cause excess heat to motor. This could lead to tripped breaker (at electrical
panel) or tripped thermal overload (on compressor motor). If this occurs, eliminate extension cord and plug
compressor directly into electrical outlet. Avoid using extension cords; use longer air hose(s) instead.
Voltage
120V
Amp Rating
Range
12-14
Table 1
Intake Filter
Risk of electric shock. Use GFCI. Use indoors only. Disconnect all connections before servicing. Use identical
replacement parts. Servicing must be performed by a licensed, qualified electrician.
Risk of electric shock. Improper use of grounding plug can result in a risk of electrical shock. Plug
must be plugged into an outlet that is properly installed and grounded in accordance with local
codes and ordinances
Do not use grounding adapter.
Table 1 shows the correct size to use depending on cord length. When in doubt, use the next
heavier gauge. The smaller the gauge number, the heavier the cord.
25 ft
50 ft
100 ft
16
12
10
Refer to Figure 2
Breather/ Oil Fill Plug- The breather/ oil fill plug allows the
crankcase to vent and where oil is added to the crankcase.
Sight Glass/ Oil Drain Plug - The sight glass/oil drain
plug gives you a view to check the oil level and where oil is
drained from the crankcase to change the oil.
Cord Length in Feet
150 ft
200 ft
250 ft
8
6
6
8
300 ft
400 ft
500 ft
4
4
2