Door Opening; Trouble-Shooting - BKS B-55600-20-1-8 Manual De Instrucciones Y De Montaje

Lector de huella digital y teclado para la introducción de código
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 140
Installation and operating instructions
B-55600-20-1-8 | B-55600-20-4-8 | B-55600-23-1-8 | B-55600-23-4-8
Fingerprint scanner and code keypad

10.1 Door opening

User code
NOTE
10.
Error description
Red LED flashes
permanently several
times per second
(approx. 2 Hz).
Red LED flashes
permanently every
two seconds
(approx. 0.5 Hz).
Green LED lights
up when an access
attempt is made, but
the door does not
open.
EN
92
If digits are entered before the user code, these are
ignored.

Trouble-shooting

Cause
No bus connection
with the control unit.
No pairing or faulty
pairing.
Blocking mode:
system is blocked
after several invalid
identifications.
Connection problem
between SC200F and
SC200R.
Help
Check the wiring or com-
mission the device.
Reset the pairing.
Scan the authorised
finger.
Clean the contacts of the
SECUREconnect 200.
Check the installation
position of the
SECUREconnect 200.
07.2017 | XX | Designed in Germany