2
Connecting and display elements
1
2
3
4
9
8
1
AS-Interface bus connection
2
Earth connection
3
Type plate (ID and IO codes)
4
LED status display for inputs
(green)
5
Sensor connections (PNP)
*) Only with type CPV..-GE-ASI-4E4A-Z: Valves can be switched off during
EMERGENCY STOP, no voltage supply to valves via AS-Interface bus
PWR LED Fault LED Meaning
on
off
AS-Interface voltage applied, no fault
off
off
No AS-Interface voltage on the bus
flashes
on
AS-Interface address not set ( = 0)
on
flashes
Short circuit / overload at the inputs or
address selector switch actuated
on
on
Bus communication failed (watchdog expired)
16
2
6
Inscription field for AS-
Interface address
7
LED status display for
valves (yellow)
Load voltage connec-
8
tion for valves *)
9
PWR LED (Power, green),
Fault LED (red)
Festo CPV..-GE-ASI-4E4A-... 0112c English
5
6
7