3.2 Connecting sensors (PNP inputs)

Use cable type KM8-M8-GSGD-... and plugs with union nuts,
thread M8x1, for connecting sensors.
Fasten the plugs with the aid of the union nuts in order to pre-
vent unintentional loosening (e.g. due to vibration). Seal unused
sensor connections with the protective caps supplied. Only then
can you comply with protection class IP 65.
PLEASE NOTE
– The inputs have been based on the IEC1131-1 type 02.
Two-wire sensors cannot however be used.
– The inputs are protected against short circuits. If a short
circuit occurs, the slave will be switched off. The AS-
Interface master regards this slave as missing. When the
short circuit has been eliminated, the slave responds
immediately as being operative.
1
2
Pin 1: 24 V
Pin 2: input Ex+3
18
2
3
3
Pin 3: 0 V
1