Finished
1/2"
Wall
(1.3 cm)
5-9/16" D.
(14.1 cm)
Plaster Guard
2-1/4" to 3"
Dome
(5.7 to 7.6 cm)
Rough-In Depth

8. Complete the Finished Wall

CAUTION: Risk of product damage. This valve contains
plastic and rubber components that may become damaged if
soldering heat is applied directly to the valve body.
CAUTION: Risk of damage to the K-2971-KS valve
assembly. When using the K-2971-KS HiFlow Valve in a
fiberglass or acrylic installation, use the Thin Wall Installation
Kit (88526).
NOTE: Thick wall installations are typically tile, plaster, marble, or
similar materials. Thin wall installations are typically fiberglass and
acrylic.
NOTE: Do not adjust the maximum water temperature at this time.
Thick Wall Installation
Provide a 5-9/16" (14.1 cm) diameter hole in the wall material.
The flat front surface of the plaster guard must be flush with the
finished wall.
Complete the finished wall.
Kohler Co.
Attachment Hole
Backing Plate
Plaster Guard
Outer Ring
Valve Stem
Dome
Finished
Wall
Backing Plate
4" D. (10.2 cm)
Plaster
Guard
2-1/4" (5.7 cm)
Rough-In Depth