Floors and walls

The floor on which the appliance is placed must have
sufficient bearing capacity. For the weight of the
appliance, see the appendix "Technical data".
There may not be any electrical wires in the
floor below the appliance and in the walls
around it.
All flammable materials must be removed from
under the appliance or protected by at least a 6
cm concrete slab.
Flammable walls bordering the appliance must
be protected by at least a 10 cm stone wall and
5 cm insulation.
Protect non-flammable walls bordering the
appliance with at least 2.5 cm insulation to
avoid cracking.
Protect a flammable floor from heat radiation
and falling ash by means of a fireproof
protective plate. See the appendix "Distance
from combustible material".
Keep enough distance between the appliance
and combustible materials such as furniture.
Ensure sufficient ventilation around flammable
materials such as a mantelpiece. See
appendix "Distance from combustible
material".
Carpets and rugs must be at least 80 cm away
from the fire.
Do not place any flammable materials within
50 cm of any convection outlets.
6

Product description

1. Flue collar
2. Convection opening (hot air)
3. Fireproof inner plates
4. De-ashing cover
5. Door
6. Latch
7. Secondary air slide
8. Primary air slide
Features of the appliance
The appliance is supplied with a glove to protect
your hand.
The appliance is supplied with a connecting kit for
the outside air supply.
The swing direction of the door can be altered. The
appliance is supplied with a left-handed door. For a
right-handed door a locking rod is needed (sold
separately). The instructions for changing the door
swing direction are provided with this locking rod.
Subject to change because of technical improvements