The assembly panel is hung onto the KMA 802 measuring
equipment's collector.
Sequence:
i Depending on the KMA 802 measuring equipment version,
the collector may project beyond the device housing. In such
a case the spacer on the rear side of the assembly panel has
to be refitted.
1.
Remove the edge protector (see Fig. 16) from the spacer.
2.
Undo the hexagon nuts and remove the spacer from the
assembly panel.
3.
Turn the spacer and screw it onto the assembly panel.
4.
Press the edge protector onto the protruding edge of the
spacer.
Fig.16
5.
Mount the assembly panel onto the KMA collector.
Fig. 17
20
6.
Move the PVC hose Item 1 for the test oil return into the test
oil tank according to Figure 18.
Fig. 18
! When doing so make sure that the hydraulic supply hoses
engage properly into place when plugged into the hose
couplings on the distributor.
7.
Plug the six hydraulic supply hoses Pos. 2 from the heat exchan-
ger into the distributor's hose couplings (sequence is optional).
Fig.19
1
2