Maintenance - Siemens simovert masterdrives Instrucciones De Servicio

Motion control convertidores de frequencia (ca-ca) forma con. en chasis
Ocultar thumbs Ver también para simovert masterdrives:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

08.2008
9

Maintenance

DANGER
Siemens AG
6SE7087-8JK50
SIMOVERT MASTERDRIVES
SIMOVERT MASTERDRIVES units are operated at high voltages.
All work carried out on or with the equipment must conform to all the
national electrical codes (BGV A3 in Germany).
Maintenance and service work may only be executed by qualified
personnel.
Only spare parts authorized by the manufacturer may be used.
The prescribed maintenance intervals and also the instructions for
repair and replacement must be complied with.
Hazardous voltages are still present in the drive units up to 5 minutes
after the converter has been powered down due to the DC link
capacitors. Thus, the unit or the DC link terminals must not be worked
on until at least after this delay time.
The power terminals and control terminals can still be at hazardous
voltage levels even when the motor is stationary.
If it is absolutely necessary that the drive converter be worked on when
powered-up:
♦ Never touch any live parts.
♦ Only use the appropriate measuring and test equipment and
protective clothing.
♦ Always stand on an ungrounded, isolated and ESD-compatible pad.
If these warnings are not observed, this can result in death, severe
bodily injury or significant material damage.
Operating Instructions
Maintenance
9-1

Hide quick links:

Publicidad

Capítulos

Tabla de contenido
loading

Este manual también es adecuado para:

Se7087-8jk5

Tabla de contenido