Connect an edge of the earth electric
cable (the cable must be characterized
by the double colour yellow/green) to
the system used for the appliance "Equi-
potential" connection (see schematic
drawing Fig. 1).

GENERAL WARNINGS

Operators have a duty to fami-
liarise themselves adequately,
using this manual before per-
forming any intervention, adopting
the specific safety requirements to
make every kind of human-compu-
ter interaction safe.
Any technical modification that
affects the operation or safety
of the machine must only be
carried out by the technical person-
nel of the manufacturer or by techni-
cians that are formally authorised by
the manufacturer. Failure to do so
exempts the manufacturer from any
liability for for any possible resulting
modifications or damage.
Even after appropriate familia-
risation, upon the first use of
the appliance, in any case si-
mulate a number of test operations
to save more rapidly the main fun-
ctions of the appliance, e.g. start-up,
shut-down, etc.
The appliance is provided alrea-
dy tested by the manufacturer
and fitted with the type of gas
and electrical supply specified on the
rating plate applies.
THE PRESENT MANUAL IS PROPERTY OF THE MANUFACTURER. ANY REPRODUCTION, EVEN PARTIAL, IS PROHIBITED.
POWER SUPPLY CONNECTIONS
Connect the opposite edge of the ear-
th electrical cable to the system used
for the "Equipotential" connection of the
area where the appliance will be instal-
led (Fig. 2).

OPERATIONS FOR COMMISSIONING

FIRST COMMISSIONING
UP / Upon completion of the opera-
tions of positioning and connection to
the power sources, perform a series of
operations such as: 1. Cleaning away
of the protective materials (oils, grease,
silicones, etc.) inside and outside of the
cooking chamber (see section 3 / Re-
moval of protective materials).
2. General checks and controls such as:
Check opening of switches & network
gate valves (water, electricity, gas
when applicable); Checking of drains;
Checking and monitoring of the exter-
nal fumes/vapour extraction; Checking
and monitoring of the protection panels
(all the panels must be fitted correctly).

DESCRIPTION OF STOP MODES

emergencies, in the event of immi-
nent danger, it is mandatory to close
all the locking devices on the supply
lines upstream the appliance (Wa-
ter-Gas-Ele).
STOPPAGE DUE TO FAULTY
OPERATIONS
Safety component / STOP: In si-
tuations or circumstances which can
be dangerous, a safety thermostat is
triggered, automatically stopping heat
generation. The production cycle is
- 12 -
Generally, in stoppage condi-
tions caused by faults and
5.
START