Switching on/off
Once the remote control is connected to the
mobile dust extractor, the mobile dust extractor
can be switched on and off with the remote con
trol.
► Press the MAN button on the remote con
trol to switch the device on and off.
Resetting the remote control
Resetting deletes the connection between a re
mote control and the mobile dust extractor.
► Hold down the connection button and the
MAN button for 10 seconds.
The LED indicator lights up purple, if the re
set has taken place.
7.7
Delete all saved devices. (MINI I / MIDI
I)
► Press and hold the connection button [1-20]
for at least three seconds.
The connection display [1-19] flashes rapid
ly.
► Press and hold both the plus and minus
button [1-18] for at least three seconds.
The mobile dust extractor confirms the com
mand by rapidly flashing three times.
8
Settings
8.1
Adjusting the suction power
► Press the plus or minus button [1-18] while
extracting.
8.2
Temperature cut-out
A temperature cut-out switches the mobile dust
extractor off when it reaches a critical tempera
ture to prevent overheating. The bottom
LED [1-18] indicates a fault.
LED lights up red
► Switch off the mobile dust extractor, let it
cool down.
► Switch on the mobile dust extractor again
after approx. five minutes.
8.3
Locking the brake [1A]
► Raise the front of the mobile dust extractor
slightly.
► Push down the brake [1-13] until it engages
into position.
► Actuate the button [1-12] to release it.
Excessive temperature
1-12
1-13
8.4
SysDoc
WARNING
Risk of injury
► Do not stand on the storage area of the
mobile dust extractor.
CAUTION
Risk of injury
► Ensure that the T-Loc or the four SysDoc
locks are closed during transport.
A Systainer can be fastened to the storage
area [1-7] with the T-Loc lock [1-8]. Systainers
without T-Loc can be secured with the four Sys
Doc locks [1-3].
9
Working
9.1
Extracting dry materials
CAUTION
Hazardous dust
Damage to the respiratory passage
► Always use a filter bag!
CAUTION
Hazardous dust
Damage to the respiratory passage
► Check that the main filter is undamaged
before extracting.
When extracting dust that exceeds the
limit value, only extract from one dust
source (power or compressed-air tool).
Observe the following when extracting dust
generated by operating power tools:
Ensure there is adequate ventilation! Observe
regional regulations!
Limit values: Exhaust air max. 50% of the fresh
air volume
Equation: room volume V
English
x air renewal rate L
R
13