Programming The "Full" & "End" Ramp Rates - Rohde ST 410 Instrucciones De Uso

Ocultar thumbs Ver también para ST 410:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 238
6.4.3. Programming the "FULL" & "END" ramp rates
Programming a "FULL" heating or cooling ramp in the firing program:
Display screen
Icon
Pr. 1
1
150
FULL
Programming the "END" of a heating ramp or cooling ramp in the firing program:
Display screen
Icon
Pr. 1
1
150
END
Meaning
Description
Program
Select the firing program that
number
is to be changed.
Indicator in the
Select the segment with the
segment
heating ramp to be changed
display
into a cooling ramp.
Heating ramp
The ramp rate for the heating
or cooling ramp is shown in
Cooling ramp
the main display.
Heating ramp
Press or hold down the
until "FULL" appears in the
Cooling ramp
main display.
Meaning
Description
Program
Select the firing program that
number
is to be changed.
Indicator in the
Select the segment with the
segment
heating ramp to be changed
display
into a cooling ramp.
Heating ramp
The ramp rate for the heating
or cooling ramp is shown in
the main display.
Cooling ramp
Heating ramp
To mark the end of the
program, push the
"END" appears in the main
Cooling ramp
display.
56 / 280
Remark
See Section 6.4.1.
See Section 6.4.1.
Possible main display:
1°C/h-999°C/h
• "FULL" heats or cools as fast as
d
key
possible.
• The "END" value is one step
above the ramp rate "999°C/h".
Remark
See Section 6.4.1.
See Section 6.4.1.
Possible main display:
1°C/h-999°C/h
• "END" ends the firing program.
• The firing program ends with the
segment in which "END" has
been programmed.
f
After "END" has been
key until
programmed, the soak/target
temperature or soak time can no
longer be selected.
• The "END" value is one step
below the ramp rate "1°C/h".

Publicidad