Querying Kiln Performance; Cooling - Rohde ST 410 Instrucciones De Uso

Ocultar thumbs Ver también para ST 410:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 238
Display screen
Icon
PAUS
WARNING
Risk of serious damage to property due to too long a soak time when using the program pause
function.
⇒ If left too long at high temperatures, kiln damage could result.
⇒ The program pause function causes the program to pause but the temperature is still
⇒ Leaving the ware too long at high temperatures could damage it or have a negative impact on
6.7.

Querying kiln performance

• The controller operates by calculating the amount of energy required by the kiln every 30 seconds (installer adjustable).
• The benefit for the user is that the power consumed is displayed at the end of the firing.
• Before the controller can display the required amount of energy in kilowatts, parameter no. 14 (see Section 10.) must
be set with the kiln performance.
• The consumption values can only be called up during firing or at the end of the firing curve. If the controller is switched
off or a new program is started, the consumption values are deleted.
• To check the required amount of energy in kilowatts (consumption values):
h
Press the
key (a small "i" is shown next to this arrow key).
• If for example 40% of full energy is required to maintain a particular ramp rate or a particular soak temperature then the
controller will apply heating power to the kiln for 12 seconds every 30 seconds.
• The kiln heating indicator will light for 12 seconds every 30 seconds.
• If the kiln has a contactor, then a loud click will be heard both when the kiln heating indicator lights up and when it
goes out. If full heating power is required, then the kiln heating indicator will remain lit. If full cooling is required, the kiln
heating indicator will remain off.
6.8.

Cooling

Upon completion of firing the controller lights all LEDs on the graphical display. The kiln is switched off and begins to cool
down on its own.
Displays during the cooling phase:
Display screen 1
411
39
⇒ To switch the controller back to idle condition, press the
Description
• While paused, the kiln temperature
display will alternate periodically with
a scrolling "PAUSED" display
• and a beep will be sounded.
maintained!
the firing results.
Icon 1
Display screen 2
HOt
En d
Remark
• The program pause facility should be
used with care.
• Program execution is suspended, and the
kiln will be held at its current temperature.
• If left too long at high temperatures kiln
damage could result.
• The pause will come to an end
automatically after a preset period.
• The pause function is preset to 2 hours at
the factory.
Icon 2
Description
As long as the kiln temperature is above
40°C, the display alternates between
display 1 & 2 every 5 seconds.
⇒ As soon as the kiln has cooled down
⇒ The firing program runs until "END" is
j
key. It can now be switched off.
63 / 280
below 40°C, the display alternates
between display 1 & 2 every 5
seconds.
displayed.

Publicidad

Tabla de contenido
loading

Productos relacionados para Rohde ST 410

Este manual también es adecuado para:

St 411

Tabla de contenido