Ravelli Rc 120 Touch steel Manual De Uso Y Mantenimiento página 168

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 234
Checking the seals
��
This operation must be carried out by a Ravelli Service Centre. Plan this type of cleaning with the Ravelli Service Centre.
When thoroughly cleaning the stove, the authorised technician must check that the gaskets of
- port
- ash drawer
- hatches
are intact. If not, they will have to be replaced.
Smoke conduit cleaning
��
This operation must be carried out by a Ravelli Assistance Centre. Schedule this type of cleaning with the Ravelli Assistance
Centre.
The stove is equipped with some hatches for cleaning the internal smoke ducts.
To clean the smoke ducts, proceed as described below:
step
action
1
Remove claddings.
2
Open the hatches.
3
Clean the ashes, eventually use a brush or similar and reassemble everything.
Note: the hatches are equipped with gaskets, therefore, before reassembling them, make sure that the gaskets are not
worn.
Note: The operation must be carried out when the stove is cold, using an ash vacuum cleaner.
1
x4
Use and maintenance manual Rc-Rv 120 Touch steel
2
Rev.1 11/03/2021
Pag.51
x4

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Rv 120 touch steel

Tabla de contenido