7.

TIG INSTALLATION (DC or AC)

TIG COLD WIRE INSTALLATION (DC or AC)
NOTE: numbers shown below are referring to Fig. 1...7
chapter 6 COMMANDS DESCRIPTION Pages 9...15.
7.1
FILLING UP THE COOLING RESEVOIR.
1.
Make sure that the switch (10) is in position "0".
2.
Unscrew Cap (7) and pour the coolant until the MAX
level indication is reached (6).
3.
Screw cap (7) back on.
Warning! When working with the cooling unit, it
should exclusively be used the coolant supplied by
Sol Welding.
7.2

SETTING UP THE GAS TANK

NOTE: only with 2 or 4 wheel trolley (See Page 15).
1.
Position the GAS tank on its support (94).
2.
Fix the bottle to the chain (93).
3.
Install the GAS regulator on the tank.
4.
Connect the GAS hose to the pressure regulator.
5.
Connect the other end of the GAS hose to connector (12).
6. Open the GAS regulator.
GB
16
7. Set the correct flow of GAS between 5
and 8 litres/min.
7.3

TIG TORCH CONNECTION

1.
Connect the power cable of the Torch to socket (8).
2.
Connect the GAS hose to connector (2).
3.
Connect the torch switch plug (9A) to socket (9).
Torch switch signal is given by a close contact between
pin 1 and 2 of the plug.
4.
In the case a water cooled TIG torch is used, connect
the water hoses "outlet and inlet", to quick connectors
(5). Connect the "Bypass" tube (19A) to the plugs (19).
Warning! When using an air-cooling Torch, connect
the "bypass" tubes (5A) and (19A) to the plugs (5) and
(19).
5.
Turn On welding machine referring to CHAPTER 10
"STARTING AND STANDARD REGULATION".
(See Page 21).
QUAD AC/DC SERIES