Suggestions for obtaining optimum mix
Suggestions for obtaining optimum mix
2.1 The triturated amalgam should be bright and have a plastic consistency. If the amalgam is
2.1 The triturated amalgam should be bright and have a plastic consistency. If the amalgam is
excessively splashy and wet looking, INCREASE trituration time or amalgamator speed.
excessively splashy and wet looking, INCREASE trituration time or amalgamator speed.
Amalgam that appears excessively dry indicates trituration time or amalgamator speed should
Amalgam that appears excessively dry indicates trituration time or amalgamator speed should
be DECREASED. Slow speed amalgamators are not recommended.
be DECREASED. Slow speed amalgamators are not recommended.
2.2 When performing adjustments, it is recommended to adjust trituration time in 2 second
2.2 When performing adjustments, it is recommended to adjust trituration time in 2 second
increments, until optimum mix is obtained. Greater adjustments may indicate amalgamator
increments, until optimum mix is obtained. Greater adjustments may indicate amalgamator
incompatibility or compromised functionality.
incompatibility or compromised functionality.
Decrease trituration time:
Decrease trituration time:
- To lengthen working time
- To lengthen working time
- If mix is too hot
- If mix is too hot
- If mix is too dry
- If mix is too dry
2.3 Properly triturated Megalloy
2.3 Properly triturated Megalloy
plasticity; however you may mull for 1-2 seconds after removing pestle to collect amalgam into a
plasticity; however you may mull for 1-2 seconds after removing pestle to collect amalgam into a
single mass.
single mass.
3. Condensation
3. Condensation
3.1 No tool is needed to open the Self-Activating capsule. Just grasp both ends of the capsule,
3.1 No tool is needed to open the Self-Activating capsule. Just grasp both ends of the capsule,
twist, and pull apart. Turn the opened capsule upside down to drop the amalgam mass into the
twist, and pull apart. Turn the opened capsule upside down to drop the amalgam mass into the
work area. Megalloy
work area. Megalloy
gentle tap may be required to free amalgam from the capsule. Do not attempt to manually
gentle tap may be required to free amalgam from the capsule. Do not attempt to manually
express mercury from the triturated mass prior to placement.
express mercury from the triturated mass prior to placement.
3.2 A plastic wafer and/or plastic mixing pestle may be seen. These have no further function and
3.2 A plastic wafer and/or plastic mixing pestle may be seen. These have no further function and
should be properly recycled.
should be properly recycled.
3.3 Condense immediately after mix is completed. Use a clean amalgam carrier to transfer
3.3 Condense immediately after mix is completed. Use a clean amalgam carrier to transfer
increments to the cavity. Pack each increment into angles and undercuts with small-faced
increments to the cavity. Pack each increment into angles and undercuts with small-faced
plugger and sufficient pressure to insure good adaptation. Build the restoration with additional
plugger and sufficient pressure to insure good adaptation. Build the restoration with additional
portions, until the cavity is slightly overfilled. Remove any mercury-rich amalgam from the
portions, until the cavity is slightly overfilled. Remove any mercury-rich amalgam from the
surface that may develop during condensation.
surface that may develop during condensation.
4. Carving/Burnishing: Carving can begin immediately after condensation. A sharp carver will give
4. Carving/Burnishing: Carving can begin immediately after condensation. A sharp carver will give
best results. The anatomy should be carved proceeding from the proximal margins towards the
best results. The anatomy should be carved proceeding from the proximal margins towards the
center of the restoration. Before the matrix band is removed, the marginal ridge should be supported
center of the restoration. Before the matrix band is removed, the marginal ridge should be supported
by a condenser. After removal of the matrix band, gingival margins may be smoothed with a curved
by a condenser. After removal of the matrix band, gingival margins may be smoothed with a curved
explorer. Burnishing setting amalgam is recommended to improve surface smoothness.
explorer. Burnishing setting amalgam is recommended to improve surface smoothness.
5. Polishing: The quality of the Megalloy
5. Polishing: The quality of the Megalloy
amalgam should be allowed to set 24 to 48 hours before polishing. See selected polishing
amalgam should be allowed to set 24 to 48 hours before polishing. See selected polishing
instrument manufacturer's directions for use.
instrument manufacturer's directions for use.
9. LOT NUMBER AND EXPIRATION DATE
9. LOT NUMBER AND EXPIRATION DATE
1. Do not use after expiration date. ISO standard is used: "YYYY/MM"
1. Do not use after expiration date. ISO standard is used: "YYYY/MM"
2. The following numbers should be quoted in all correspondence.
2. The following numbers should be quoted in all correspondence.
• Reorder number
• Reorder number
• Lot number on package
• Lot number on package
• Expiration date on package
• Expiration date on package
©2008 DENTSPLY International. All rights reserved. Printed in U.S.A.
©2008 DENTSPLY International. All rights reserved. Printed in U.S.A.
Manufactured by:
Manufactured by:
DENTSPLY Caulk
DENTSPLY Caulk
38 West Clarke Avenue
38 West Clarke Avenue
Milford, DE 19963 U.S.A.
Milford, DE 19963 U.S.A.
Tel.: 1-302-422-4511
Tel.: 1-302-422-4511
www.dentsply.com
www.dentsply.com
0120
0120
© 008-09- DENTSPLY International. All Rights Reserved.
Increase trituration time:
Increase trituration time:
- To shorten working time
- To shorten working time
- If mix is too wet
- If mix is too wet
EZ Amalgam does not require mulling to produce a smooth
®
EZ Amalgam does not require mulling to produce a smooth
®
EZ amalgam is now ready for immediate placement and condensation. A
®
EZ amalgam is now ready for immediate placement and condensation. A
®
EZ Amalgam restoration will be enhanced by polishing. The
®
EZ Amalgam restoration will be enhanced by polishing. The
®
Distributed by:
Distributed by:
DENTSPLY Canada
DENTSPLY Canada
161 Vinyl Court
161 Vinyl Court
Woodbridge, Ontario
Woodbridge, Ontario
L4L 4A3 Canada
L4L 4A3 Canada
DENTSPLY D
T
GmbH
DENTSPLY D
T
GmbH
E
REY
E
REY
De-Trey-Str. 1
De-Trey-Str. 1
78467 Konstanz, Germany
78467 Konstanz, Germany
Tel.: 49-7531-583-0
Tel.: 49-7531-583-0
www.dentsply.de
www.dentsply.de
Form #503051 (R 9/22/08)
Form #503051 (R 9/22/08)


Publicidad

Tabla de contenido
loading

Tabla de contenido