MAINTENANCE
Follow the maintenance instructions indicated be-
low to operate the machine correctly.
Safety Rules
Do not use water jets on the machine. Disconnect
the machine from the power line by turning the
lever of the omnipolar disconnecter, of the elec-
tric mains, to the "0" rest position, remove the
plug and close the water interception valve before
carrying out maintenance and/or cleaning opera-
tions. If the machine malfunctions, do not attempt
to repair it yourself and immediately contact tech-
nical support. In case of damage to the power
supply cord, turn off the machine immediately,
close the water and contact the technical assi-
stance service. Avoid replacing it autonomously.
Perform cleaning/maintenance with the machine
cold, preferably wearing protective gloves.
Cleaning the Machine
Warnings: For the best results and in
compliance with current regulations,
change the water in the boiler and pi-
pes at when starting the machine every
day.
This advice is for indication purposes only: main-
tenance and cleaning schedules depend on the
use of the machine.
After each use
1) Clean the steam wand.
2) Clean the filter-holder and filters.
Daily
1) Clean the cup rack and the drip tray.
2) Clean the bodywork.
3) Clean the group gasket with the brush sup-
plied.
4) Wash the group as follows: clip the filter hold-
er with the blind filter supplied to the group
and start a delivery several times.
5) Immerse the filter-holders and filters in boiling
water for a few minutes to any coffee oils and
use a cloth or sponge to remove it.
For washing and cleaning, do not use
solvents, detergents or abrasive spong-
es. Only use specific products for cof-
fee machines. Wash the bodywork us-
MOD.
ing a cloth soaked in water and/or neutral
detergent, taking care to dry the surface well be-
fore reconnecting the machine to the mains elec-
tricity. Use water to wash the cup rack and the
drip tray.
To wash the tank after having extracted it, use wa-
ter and neutral detergents and perform thorough
rinsing. Reinsert the tank and the silicon tubes.
Safety thermostat - Manual resetting
Warning! The operation descri-
bed below must be only perfor-
med by an installation techni-
cian
manufacturer.
During machine operation the overheating of the
resistance in the boiler can trig, disconnecting the
power, the safety thermostat that prevents the oc-
currence of more damages to the boiler. To resto-
re normal operation, it is necessary to solve the
fault that has caused the intervention of the safety
thermostat and then restore the normal condition
by pressing the red button (RESET) (Fig. 08).
Correct disposal of the product
(electric and electronic waste)
(Applicable in the countries of the European
Union and in those with waste sorting systems)
The label affixed on the product and
on the documents indicates that the
product must be disposed of with other
domestic waste at the end of its life
cycle. To avoid any damages to the environment
or health caused by improper waste disposal, the
user must separate this product from other types
of waste and recycle it responsibly to promote the
sustainable reuse of material resources.
Domestic users should contact the reseller from
whom they purchased the product or the relevant
office in their area to obtain all information about
waste sorting and recycling of this type of product.
Corporate users should contact their supplier to
check the terms and conditions of the purchase
agreement.
This product must not be disposed of with other
industrial waste.
5
BEZZERA MAGICA - MITICA
authorised
by
the