Hitachi SJ300 Serie Guía Referencia Rápida página 35

Ocultar thumbs Ver también para SJ300 Serie:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Analog Output Function Listing
The following table shows all eight functions available for assignment to
the three analog output terminals:
• Terminal [FM], option set by C027
• Terminal [AM], option set by C028
• Terminal [AMI], option set by C029
Option
Function
Code
Name
00
Output
frequency
01
Output current Motor current (% of
02
Output torque
03
Digital output
frequency
04
Output voltage Rated output voltage to
05
Input power
06
Electronic
thermal
overload
07
LAD
frequency
Description
Actual motor speed,
represented by PWM
signal
maximum rated output
current), represented by
PWM signal
Rated output torque
Output frequency (avail-
able only at [FM] output)
motor
Rated input power
Percentage of electronic
overload attained
Internal ramp generator
frequency
33
Corresponding
Signal Range
0 to max. frequency in Hz
0 to 200%
0 to 200%
0 to max. frequency in Hz
0 to 100%
0 to 200%
0 to 100%
0 to max. frequency in Hz

Publicidad

Tabla de contenido
loading

Tabla de contenido