Programming Error Codes
The SJ300 inverter operator keypad displays a special code (begins with
the
character) to indicate a programming error. Programming errors
exist when one parameter conflicts with the meaningful range permitted
by related parameter(s). Note that particular real-time frequency (speed)
input levels can cause a conflict in some situations. After a conflict exists,
the error code will appear on the display, or you can view it later with
D090 in Monitor Mode. Also, the PGM LED on the display will flash
ON/OFF when programming. These indications are automatically cleared
when the parameter is corrected to the allowed range.
Prg Error Code
001 201
002 202
004 204 304
005 205 305
006 206 306
012 212
015 215
016 216
021 221
025 225
031 231
032 232
035 235 335
036
037
Function code of
parameter out of
bounds
A061 / A261
A062 / A262
A003 / A203 / A303
F001, A020 / A220 /
A320
A021 to A035 /
A221 to A235
A321 to A325
A062 / A262
F001, A020 / A220
A021 to A035 /
A221 to A235
A061 / A261
F001, A020 / A220
A061 / A261
A062 / A262
F001, A202 / A220 /
A320
A021 to A035
A038
34
Boundary defined by...
<, >
Base parameter
>
A004 / A204 / A304
>
>
>
>
>
A061 / A261
>
>
<
A062 / A262
<
<
B082
<
<
<
<