Thermor AEROMAX SPLIT 2 Manual De Instalación página 14

Ocultar thumbs Ver también para AEROMAX SPLIT 2:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 59
Warnings
1.2.
Installation site of the water heater version 270 l
Floor bearing capacity:
Area required:
Height underneath the ceiling:
Recommended installation site: •
1.3.
Installation site of the water heater version 200 l
Type of wall bearing
the suspended water
heater:
(the mounting template
has been printed on the
package)
Area required:
Height underneath the
ceiling
Recommended installa-
tion site:
12
Presentation
655
588 without
safety device
650 recommended
Rather thin walls (of type drywall): Threaded pins of Ø
10mm, penetrating the wall and connected by profiles or
counter plates.
Thick solid walls (concrete, stone, brickwork): Anchor bolts
of Ø 10mm or drill holes for dowels of type MOLY Ø 10mm.
If the wall the device is mounted onto is not capable of bea-
ring the respective weight, the device can be put on a rack.
It is absolutely necessary to affix the upper bracket. Please
use the rack recommended by the manufacture.
588 x 603 (l x d), see below figures
588 x 600 (l x d) when installed on a universal tripod. See
diagram below for integration in a closet.
> 1.65 m
In heated rooms
Installation in a cupboard
with stirrups
588
Load capacity of at least 400 kg for the surface
area bearing the water heater
655 x 650 (l x d), see below figures
> 1.70 m
In heated rooms
588
604
without safety device
Optimized installation in a closet
with universal tripod
603
588
Installation
600

Publicidad

Tabla de contenido
loading

Tabla de contenido