USER GUIDE
FAULT AND REMEDIAL MEASURES
In most cases, you will be able to troubleshoot problems easily by yourself. Before you contact
us, please refer to the following table. This will help you save a lot of work and possible
expenses. If you are unable to remove the faults, please contact with the local suppliers directly.
Please remember that tampering by unauthorized persons will invalidate your warranty and
compensation claims and will lead to additional costs.
Error
Reasons
The pump fails
1.Power supply interruption/
to make
access failure of
operation or the
external power supply.
pump
2.The power line or plug is
stops suddenly
defective.
during
3.The mechanical seal is
operation.
sucked.
4.Due to the pressure in the
pipeline, the pressure switch
shall shut off the circuit.
5.The installation height of
faucet has exceeded the
pressure value of pressure
switch.
6.Other faults.
1.The dirty water or grainy
Insufficient flow
rate/flow
wastewater will reduce the
rate absence (or
suction capacity of pump.
selfabsorption
2.Hose/pipeline/filter screen
failure)
plugging.
3.The hose/pipeline system is
damaged.
4.The water inlet is excessi-
vely soft, as a result, the water
inlet fails to draw water due to
the suction
flattening during the pump
operation.
5.Due to the air in the pump
head, the pump fails to be
completely filled with
water.
6.Please immerse the water
inlet in water for 10cm at least.
7.The joint of suction pipeline
is untighted.
1.The pipeline or pump suffer
The product is
closed in a
from abnormal obstruction and
short period.
the thermal
circuit breaker has cut off the
electrical circuit.
2.Due to the excessively
high environment or water
temperature, the thermal
circuit breaker has cut
off the electrical circuit.
3.Due to the pressure
in the pipeline, the pressure
switch shall shut off the power.
4.The obstruction is caused by
the damaged impeller.
The pump is started
frequently.
Response measures
1.Check the fuse device and
electrical connection and
switch on the external power
supply.
2.Ask the professional electri-
cians to make inspection.
3.Considering that the
mechanical seal will suffer
from resistance when it is idle
for long period, please switch
off the pump and pull out the
power plug.
Please cool the pump and
apply the slot-type screwdriver
to rotate the tail of shaft.
When the
shaft becomes flexible, please
power on to start the pump.
4.Please open the faucet, at
this moment, the pressure
TECHNICAL DATA
switch will power on automati-
cally after depressurization.
5.When necessary, please
adjust the pressure setup
value of pressure switch.
6.Please ask the mainte-
nance department to make
inspection.
1.Please clean up the filter
screen and replace the dama-
ged spare parts (such as, the
worn impeller and so on).
2.Dredge the pipeline/-
clean up the filter screen.
3.Replace the pipeline.
4.Please replace the threaded
reinforcing anti-vacuum
hose or
pressure-proof hard tube.
DECLARATION CE
5.Please fill the pump
head up with water.
6.Please check whether
the water source is enough,
then, immerse the
water inlet in water for more
The products listed above are in compliance with:
than 10cm.
7.Please replace the
Directive 2006/42/CE and with the Standard EN 809 (Machine security), Directive EMC
joint sealing element and
2014/300/EU (electromagnetic compatibility), Directive 2014/35/EU (Lower voltage) and with
completely seal the joint.
the European Standard EN 60335-2-41; EN-ISO 3744 (Noise emission values in instruction
manual). Directive 2005/88/EC (noise emission). Directive 2011/65/UE.
1.Please get rid of the
plugging matters, then, power
on and draw water after the
pump has cooled
completely.
2.Please ensure that the
water and environment
temperature is less than
35°C, then, power on and
draw water.
3.Please open the faucet,
at this moment, the pressure
switch will start automatically
after depressurization.
4.Please ask the mainte-
nance department to make
inspection.
6
Error
Reasons
1.Pipeline or joint leakage.
2.The suction culvert fails to
be installed with check valve.
3.The air pressure value in the
pressure tank is excessively
low.
4.The inner container of
pressure tank is sucked.
Engine
Electric
Single-phase (V)
230
Power (W)
1.300 (input) - 1.150 (output)
Maximum flow (l/h)
4.800
Pressure tank capacity (l)
24
Height (m)
8
IP
X4
Pump body
Inox
Other features
1m cable, 85dB
Weight (kg)
17 (N.W) / 17,5 (G.W)
Model
ZONDA 130S M 240
Eduard Rodríguez (Director)
MEBA SL.U.
11th December 2020
EN
Response measures
1.Please check the pipeline
and joint and make the correct
installation again to avoid the
leakage.
2.Please install the check
valve on the water inlet.
3.Please refer to the
recommended air pressure
tank as specified in the tail
of pressure tank and make
air inflation according to the
labeling value.
4.The inner container will
be sucked when the internal
pressure in the pressure tank
is extruded for long period
as long
as the pump is idle for a
long time, at this moment,
please draw water and close
the water valve slowly, as a
result, the
sucked part will be opened
after multiple operations,
followed by normal operation.
Reference
210143