Filling The Container; Spraying - Stihl SG 31 Manual De Instrucciones

Ocultar thumbs Ver también para SG 31:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

The pressure in the solution container
must not drop any more than 0.5 bar
(7.25 PSI) within the next 30 minutes.
Operate spray gun trigger –
N
pressure must escape.
Release spray gun trigger –
N
pressure must not escape.
Pull out piston manometer –
N
pressure must escape audibly.
Completely depressurize the
N
solution container.
SG 31

Filling the Container

The solution container must not be
under pressure.
Unscrew the pump from the
N
container.
Stand the container securely on a
N
level surface.
Pour thoroughly mixed spray
N
solution through the opening
(arrow) – do not exceed maximum
capacity (check max mark on
scale).
Refit pump in the container.
N

Spraying

Visual Inspection
Do not operate your machine if any of its
components are damaged. It is
particularly important to check the
solution container and hose connections
for leaks.
Spraying
Build up pressure – move the pump
N
handle up and down several times
until the piston manometer shows
the required working pressure – see
"Pressures / Spray Rates" below.
Lock the pump handle.
N
Working pressures / spray rates – see
"Specifications".
English
11

Publicidad

Capítulos

Tabla de contenido
loading