Check with a qualified electrician or serviceman if the
grounding instructions are not completely understood, or if
in doubt as to whether the product is properly grounded. Do
not modify the plug provided; if it will not fit the outlet, have
the proper outlet installed by a qualified electrician.
This product is for use on a nominal 120-volt circuit and has
a grounding plug that looks like the plug illustrated below.
Make sure the product is connected to an outlet having the
same configuration as the plug. No adapter should be used
with this product.
A=Ground
B=Grounding Pin
C=Outlet
EXTENSION CORDS- It is preferable to use extra air hose
instead of an extension cord to avoid voltage drop and power
loss to the motor, and to prevent overheating. If an extension
cord must be used, ensure it meets the following criteria:
Three wire cord with a three blade grounding plug, and
a three slot receptacle that will accept the plug on the
unit.
Good condition
No longer than 50 feet.
12 gauge or larger.
Wire size increases as gauge number decreases . For
example, 10 AWG and 8 AWG wire is acceptable,
whereas 14 or 16 AWG are NOT acceptable .
COMPRESSOR LUBRICATION
CAUTION
Do not operate without lubricant or with inadequate
lubricant . lngersoll Rand is not responsible for
compressor failure caused by inadequate lubrication .
SYNTHETIC LUBRICANT- We recommend Ingersoll-Rand
synthetic compressor lubricant from start-up. See the
WARRANTY section for extended warranty information.
ALTERNATE LUBRICANTS- You may use a petroleum-
based lubricant that is premium quality, does not contain
detergents, contains only anti-rust, anti-oxidation, and anti-
foam agents as additives, has a flashpoint of 440°F (227°C)
or higher, and has an auto-ignition point of 650°F (343°C) or
higher.
22204861 Rev. C
RELEASED 26/Jan/2020 20:37:54 GMT
NOTICE
See the petroleum lubricant viscosity table below. The table
is intended as a general guide only. Heavy duty operating
conditions require heavier viscosities. Refer specific operating
conditions to your dealer for recommendations.
Temperature Around
Viscosity @ 100°F
Unit
(37 .8°C)
°F
°C
SUS Centistokes
40 &
4.4 &
150
below
below
40 - 80
4.4 - 26.7
500
80 • 125
26.7- 51.0
750
If you use a petroleum-based compressor lubricant at
start-up and decide to convert to Ingersoll-Rand synthetic
compressor lubricant later on, the compressor valves must be
thoroughly decarbonized and the crankcase must be flushed
before conversion.
COMPRESSOR PUMP FILLING PROCEDURES:
1.
Unscrew and remove the oil fill plug (A).
2.
Slowly fill the crankcase with lubricant until the lubricant
reaches the top thread of the oil fill opening and the top
of the sight glass. Crankcase capacity is one (1) pint (0.5
liters).
3.
Replace the oil fill plug HAND TIGHT ONLY.
Filling Procedures
EN
Viscosity
Grade
ISO
SAE
32
32
10
110
100
30
165
150
40