PROBLEM
Improper line voltage.
Wiring or electric service panel too small
Lights flicker or dim
Poor contact on motor terminals or starter
when running
connections.
Improper starter overload heaters.
Poor power regulation (unbalanced line).
Moisture in crankcase
Detergent type lubricant being used.
or
"milky" appearance in
Extremely light duty cycles.
petroleum lubricant or
Unit located in damp or humid location.
rusting in cylinders
lubricant viscosity too high.
Improper line voltage.
Wiring or electric service panel too small
Poor contact on motor terminals or starter
connections.
Improper starter overload heaters.
Poor power regulation (unbalanced line).
Drive belts too tight or misaligned.
Motor overload trips
Compressor valves leaky, broken, carbonized
or draws excessive
or loose.
current
Cylinder(s) or piston(s) scratched, worn or
scored.
Connecting rod. piston pin or crankpin
bearings worn or scored.
Defective ball bearings on crankshaft or motor
shaft.
Leaking check valve or check valve seat blown
out.
Ambient temperature too low.
Bad motor.
Improper line voltage.
Wiring or electric service panel too small
Motor will not start
Poor contact on motor terminals or starter
connections.
Improper starter overload heaters.
Bad motor.
22204861 Rev. C
RELEASED 26/Jan/2020 20:37:54 GMT
POSSIBLE CAUSE
POSSIBLE SOLUTION
Check line voltage and upgrade lines as required.
Contact electrician.
Install properly sized wire or service box. Contact
electrician.
Ensure good contact on motor terminals or starter
connections.
Install proper starter overload heaters. Contact
electrician.
Contact power company.
Drain existing lubricant and refill with proper
lubricant.
Run unit for longer duty cycles.
Relocate unit.
Drain existing lubricant and refill with proper
lubricant.
Check line voltage and upgrade lines as required.
Contact electrician.
Install properly sized wire or service box. Contact
electrician.
Ensure good contact on motor terminals or starter
connections.
Install proper starter overload heaters. Contact
electrician.
Contact power company.
Adjust belts to proper tension and alignment.
Inspect valves. Clean or replace as required.
Install valve kit.
Repair or replace as required.
lnspect all. Repair or replace as required.
Inspect bearings and replace crankshaft assembly
if required.
Replace check valve.
Relocate unit to warmer environment
Install crankcase heater kit.
Convert to synthetic lubricant.
Replace
Check line voltage and upgrade lines as required.
Contact electrician.
Install properly sized wire or service box. Contact
electrician.
Ensure good contact on motor terminals or starter
connections.
Install proper starter overload heaters. Contact
electrician.