Abicor Binzel ABIPLAS WELD CT Serie Instructivo De Servicio página 35

Ocultar thumbs Ver también para ABIPLAS WELD CT Serie:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

®
ABIPLAS
WELD CT
6.4 Mounting the torch body at the complete fastener
1
16
15
14
13
1
Torch body (equipped)
2
Connection nut
3
2 cylinder screws M5x20
4
Complete fastener
5
Cable assembly
6
Nut M10x1
Fig. 6
Mounting Plasma segment holder
2
3
12
7
Guide tube
8
Set screw
9
Nut M10x1
10 Guide
11 Knurled screw
1 Fasten the complete fastener (4) to the robot
2 Introduce guide tube (7) from behind through the bore of the complete
fastener (4), screw it down and secure it with the set screw (8).
3 Unscrew cylinder screws (3) and slide cable assembly (5) through the
complete fastener (4) as far as it will go. Positioning is possible in 90° steps.
4 Connect the cable of the safety switch-off circuit to the CAT torch mount.
5 Introduce torch body (1) from the front into the cable assembly (5) and
secure it with connection nut (2).
6 Fix fastener (16) to torch neck (1) with cylinder screws (14). Use fastener
(16) only with ABIPLAS
7 Screw guide (10) to guide tube (7) with nut (9).
8 Screw knurled screw (11) of the cold-wire feeder (12) into fastener (16).
4
11
12 Cold-wire feeder
13 Nozzle
14 2 cylinder screws M4x8
15 Cylindrical pin 4m6x10
16 Fastener
®
WELD CT 250 CT20.
6 Putting into operation
10
EN - 13
5
6
7
8
9

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Abiplas weld 150 ct20Abiplas weld 250 ct20

Tabla de contenido