Power Supply Specifications; Input Wiring Specifications - ESAB Cutmaster 120 Manual De Instrucciones

Ocultar thumbs Ver también para Cutmaster 120:
Tabla de contenido

Publicidad

ESAB CUTMASTER 120
2.04 Power Supply Specifications
ESAB Cutmaster
®
120 Power Supply Specifications
380 VAC (360 - 440 VAC), Three Phase, 50/60 Hz
Input Power
400 VAC (360 - 440 VAC), Three Phase, 50 Hz
Input Power Cable
Power Supply includes input cable.
Output Current
30 - 120 Amps, Continuously Adjustable
Power Supply Gas
Particulates to 5 Microns
Filtering Ability
ESAB Cutmaster
120 Power Supply Duty Cycle *
®
Duty Cycle Ratings @ 40° C (104° F)
Ambient Temperature
Operating Range 0° - 50° C
Duty Cycle
Ratings
All Units
Current
DC Voltage
* NOTE: The duty cycle will be reduced if the primary input power (AC) is low
or the output voltage (DC) is higher than shown in this chart.
NOTE!
IEC Rating is determined as specified by the International Electro-Technical Commission.
These specifications include calculating an output voltage based upon power supply rated
current. To facilitate comparison between power supplies, all manufacturers use this out-
put voltage to determine duty cycle.
Power Supply Dimensions & Weight
10.75"
273 mm
Art # A-08358
16.375"
416 mm
30.5"
63 lb / 28.6 kg
774.7 m
2-2
INTRODUCTION
N/A
80%
100%
IEC
IEC
120
110
128
124
Ventilation Clearance Requirements
Art # A-07925_AB
24"
610 mm
6"
150 mm
Manual 0-5398
2.05 Input Wiring Specifications
ESAB Cutmaster
®
120 Power Supply Input Cable Wiring Requirements
Input voltage
Freq
Power Input
Volts
Hz
kVA
380
50
23
3 Phase
400
50
23.6
Line Voltages with Suggested Circuit Protection and Wire Sizes
Based on National Electric Code and Canadian Electric Code
NOTE!
Refer to Local and National Codes or local authority having jurisdiction for proper wiring
requirements.
The suggested sizes are based on flexible power cable with power plug installations. For
hard-wired installations refer to local or national codes.
I 1 max is taken at TDC rated minimum duty cycle.
I 1 eff is taken at TDC 100% rated duty cycle.
Manual 0-5398
INTRODUCTION
ESAB CUTMASTER 120
Suggested Sizes
Fuse
Flexible Cord
Flexible Cord
I max
I eff
(amps)
(Min. AWG)
(Min. mm
35
32
40
8
10
34
31
40
8
10
)
2
2-3

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Sl100 1torchCutmaster 100

Tabla de contenido