ESAB CUTMASTER 120
5.02 Maintenance Schedule
NOTE!
The actual frequency of mainte-
nance may need to be adjusted
according to the operating environ-
ment.
Daily Operational Checks or Every Six Cutting
Hours:
1. Check torch consumable parts, replace if dam-
aged or worn.
2. Check plasma and secondary supply and pres-
sure/flow.
3. Purge plasma gas line to remove any moisture
build-up.
Weekly or Every 30 Cutting Hours:
1. Check fan for proper operation and adequate air
flow.
2. Inspect torch for any cracks or exposed wires,
replace if necessary.
3. Inspect input power cable for damage or exposed
wires, replace if necessary.
Six Months or Every 720 Cutting Hours:
1. Check the in-line air filter(s), clean or replace as
required.
2. Check cables and hoses for leaks or cracks,
replace if necessary.
3. Check all contactor points for severe arcing or
pits, replace if necessary.
4. Vacuum dust and dirt out of the entire machine.
CAUTION
!
Do not blow air into the power sup-
ply during cleaning. Blowing air into
the unit can cause metal particles
to interfere with sensitive electrical
components and cause damage to
the unit.
5-2
5.03 Common Faults
Problem -
Common Cause
Symptom
Insufficient
1. Cutting speed too fast.
Penetration
2. Torch tilted too much.
3. Metal too thick.
4. Worn torch parts
5. Cutting current too low.
6. Non - Genuine ESAB parts used
7. Incorrect gas pressure
Main Arc
1. Cutting speed too slow.
Extinguishes
2. Torch standoff too high from
workpiece.
3. Cutting current too high.
4. Work cable disconnected.
5. Worn torch parts.
6. Non - Genuine ESAB parts used
Excessive Dross
1. Cutting speed too slow.
Formation
2. Torch standoff too high from
workpiece.
3. Worn torch parts.
4. Improper cutting current.
5. Non - Genuine ESAB parts used
6. Incorrect gas pressure
Short Torch Parts
1. Oil or moisture in air source.
Life
2. Exceeding system capability
(material too thick).
3. Excessive pilot arc time
4. Gas pressure too low.
5. Improperly assembled torch.
6. Non - Genuine ESAB parts used
Difficult Starting 1. Worn torch parts.
2. Non - Genuine ESAB parts
used.
3. Incorrect gas pressure.
SERVICE
Manual 0-5398
5.04 Fault Indicator
At initial power up, two lights will temporarily illuminate for 2-3 seconds to show the version of software used.
To determine the first digit, count the function indicators left to right, 1 through 5. To determine the second digit
count the pressure indicators, reading from bottom to top, 0 through 7. In the example below the Temp indicator
and 75 psi indicators are on indicating the version would be 2.3.
7
6
5
A
MAX
MIN
PSI
BAR
MAX
MAX
4
+
3
2
1
MIN
MIN
0
!
Art# A-07988
1 2 3 4
5
!
When the "Fault" indicator is ON or blinking it will be accompanied by one of the pressure indicator lights
depending on what the Fault is. The following table explains each of those Faults.
Pressure
Fault
Indicator
Max
Over Pressure
90
Internal Error
85
Check Consumables
80
Consumables Missing
75
Start Error
70
Parts in Place
65
Input Power
Min
Under Pressure
NOTE!
Fault explanations are covered in the following tables.
Manual 0-5398
ESAB CUTMASTER 120
SERVICE