Electrical
TABLE I: MOTOR, SWITCH, & CORD SPECIFICATIONS
Model
Motor
Number
HP
SCC10300320M-01
2
Factory Connected for 230V/3Ø as shown
Z1
Y1
X1
230 Volt
Power Supply
White
Red
Z1 Y1 X1
U1
V1
Motor
Windings
Figure 2: 230 Volt 3 Phase Wiring Connections
Connect for 460V as shown.
460 Volt
Power Supply
White
Red
W2
V2
U2
Z1
Y1
X1
Z1 Y1
X1
U1
V1
W1
Motor
Windings
Figure 3: 460 Volt 3 Phase Wiring Connections
Motor
Full
Voltage
Load Amps
Required (Amps) in ft. (m)
230/460/60/3
8.9/4.5
Z2
Y2
X2
Black
W2
V2
U2
X2 Y2 Z2
W1
Motor
Windings
Black
X2
Y2
V2
U2
W2
X2 Y2 Z2
Motor
Windings
Individual
Cord
Branch Circuit
Length
15/15
20 (6.1)
Control Panels
motor before connecting controls or power supply.
Adhere to local electrical codes governing pump and
control installations.
A control panel is not included with the pump.
Install simplex or duplex control panel (purchase sepa-
rately) for proper pump operation. A full range of con-
trols and switches is listed in our catalog.
If a Sta-Rite control panel is not used, install a control
panel with circuit breaker or fused disconnect as
required by local code. Use magnetic starters with ambi-
ent compensated overload protection. Three phase units
require three line protection; single phase units require
only one line protection. Inadequate protection voids the
warranty.
Control Panel Overload Adjustment –
Three Phase
NOTICE: See your control panel installation and operat-
ing instructions before adjusting overload setting.
Set the overload protective device to the nameplate full
load current.
Size the overload protective device so that the trip cur-
rent is 115% of the nameplate full load current.
Z2
Minimum
Discharge
Water Level
Adapter
in inches (mm)
Size
19-1/2 (496)
3" NPT
Risk of electric shock. Ground pump and
4
Max Temp.
Rating (°F)
Int.
Cont.
122
105