Operating Modes - Cebora WF5 Manual De Istrucciones

Carro arrastrahilo
Ocultar thumbs Ver también para WF5:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

3.2
Connector BA (external signals)
NOTE: All control signals must be with contacts
clean and no voltage.
Pin
Signal
Push-pull torch
A
Motor +
motor positive
supply
Push-pull torch
B
Motor-
motor negative
supply
C
Wire_inch
Wire increment
Insulated earth
D
GND_ISO
reference for
external I/Os
E
Not used
F
Wire_retract
Wire retract
G
Gas Test
Gas test
H
Arc_on
Arc on
I
Arc_on
J
Not used
Collision protection
K
Coll_prot+
+
Collision protection
L
Coll_prot-
-
M
Not used
N
12V_Iso
12 V Insulated
3301059/A
Description
Type
32 V
2 A
Clean
contact
Dry
contact
Dry
contact
Dry
contact
1 A 125
ac 110 V
dc max
Dry
contact
12
Vdc
80mA
3.3
BD Connector (CAN bus)
Console – wire feeder
Pin
A
B
C
D
E
F
CAN1_Vdc
G
H
I
J
CAN1_0Vdc
4

OPERATING MODES

The following wire feeder operating modes can be
selected in the TIG power source menu:
Continuous, asynchronous and synchronous
4.1
Continuous mode
In this operating mode, the wire feeder delivers
wire continuously. The following parameters can
be configured:
Wire feeder start:
- AUTO: the wire feeder starts automatically as
soon as peak current begins to flow to the welding
workpiece.
- ext: the wire feeder starts when the Wire_inc
signal is activated in connector BA or from the
fieldbus by enabling the Wire_inc bit. The motor
always starts on peak current when peak current is
flowing through the welding workpiece
High speed:
Wire feed speed during welding:
[0.1m/min- 10m/min]
Signal
Housing
0V_24Vdc
Housing
0V_55Vdc
+55Vdc
CAN1-H
+24Vdc
CAN1-L
20

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

1649.00

Tabla de contenido