Connecting the Electricity

(Only hobs with automatic ignition or elec-
tric hotplates)
Before connecting the hob to the electric
mains, check that the voltage and fre-
quency of the mains matches what is
shown on the hob's rating plate, which is
located lower down, and on the guarantee
certificate or, where appropriate, the tech-
nical datasheet supplied, which should be
kept together with this manual.
When the appliance is connected to the
electricity main by a socket:
* Fit a standard plug suited to the load indi-
cated on the data label to the cable. Fit the
wires following figure 6, taking care of res-
pecting the following correspondences:
Letter L (live) = brown wire;
Letter N (neutral) = blue wire;
Earth symbol = green - yellow wire.
* The power supply cable must be positio-
ned so that no part of it is able to reach an
overtemperature of 65 K.
* Never use reductions, adapters of shunts
for connection since these could create
false contacts and lead to dangerous over-
heating.
The connection is made via an omnipolar
switch or plug where accessible, which is
suitable for the intensity to be tolerated
and which has a minimum gap of 3 mm
between its contacts, which will ensure
disconnection in case of emergency or
when cleaning the hob. It should also be
correctly earthed in line with current stan-
dards.
The connection should include correct
earthing, in compliance with current
norms.
If the flexible supply cable fitted to these
appliances ever needs to be changed, it
should be replaced by TEKA's official service.
If the mains cord is damaged, should
be replaced by the manufacturer or its
after sales service.
Need to allow the disconnection of the
network device after installation, via a
plug or switch accessible.
All our appliances are designed and
manufactured in compliance with Euro-
pean standards EN 60 335-1 and EN 60
335-2-6 plus the relative
amendments.
The appliance complies with the provi-
sions of the following EEC Directives:
- 2004/108/EC regarding to
electromagnetic compatibility.
- 2006/95/EC regarding electrical safety.
fig. 6