Gas Conversion - Teka HF LUX 60 4G AL NAT Instrucciones Para La Instalación

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

GB_61401134_en.qxd 27.02.2015 14:52 Page 10
Gas convers�on
ImportantY
Any alterat�on that �s to be made to the
appl�ance to convert �t to a d�fferent
type of gas should only be carr�ed out
by a qual�f�ed techn�c�an.
Informat�on for Techn�cal Ass�s-
tance: whenever the type of gas or the
appl�ance's pressure �s changed, the new
regulat�on plate should be placed on top of
the old one so that the new features can
be seen after the change.
The tasks �nvolved �n convers�on are:
* Replace the �njectors.
* Adjust the taps' m�n�mums.
The �njectors requ�red for each gas type
are shown �n table 1.
To replace the �njectors, follow these �ns-
truct�ons:
1 Remove the gr�ds and upper parts of the
burner so that the �njector can be seen.
Table 1
°
2 Us�ng a number 7 p�pe spanner, remove
the �njectors and replace them w�th the
new ones. Take care to press the �njector
down f�rmly so that there �s no leakage.
3 Replace the gr�d and burners that were
prev�ously removed.
When the �njectors have been changed,
th�s �s how to adjust the m�n�mums:
1 Turn the burners on to the�r m�n�mum.
2 Pull the taps' controls f�rmly upwards to
remove them.
3 Use a sl�m, grooved screwdr�ver to turn
the screw located to the r�ght or �n the
centre of the gas tap's shaft (the flame
�ncreases when you turn to the left and
decreases when you turn to the r�ght).
4 When properly adjusted, check that the
flame does not go out when you turn the
knob qu�ckly from max�mum to m�n�-
mum.
TEKA INDUSTRIAL, S.A. assumes no
respons�b�l�ty for any hob malfunct�on �f the
gas convers�on or the adjustment of the
burners' m�n�mums has not been carr�ed
out by TEKA's off�c�al personnel.
10

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Hf lux 60 4g al butHf lux 50 4g al natHf lux 50 4g al butHlx 60 4g al natHlx 60 4g al butHf lux 50 4g al al ci nat ... Mostrar todo