Descargar Imprimir esta página

Balluff BTL5 Serie Instrucciones Breves página 5

Transductor de desplazamiento micropulse
Ocultar thumbs Ver también para BTL5 Serie:

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 10
BTL5-A/C/E/G1 _-M_ _ _ _-HB/WB-FA_ _/F_ _-C
Micropulse Linear Transducer – Rod Style
Installation
BTL5...HB/WB-...-C
- axial
55
60
29.5
for Hookspanner
Ø 58-62
BTL5...HB/WB-...-C
- radial
60
Ø 5
for Hookspanner
Ø 58-62
M18x1.5
24
Ensure that no strong
electrical or magnetic
fields are present in the
immediate vicinity of the trans-
ducer.
The contact surface of the trans-
ducer must be completely con-
tacted by the mounting surface.
The O-ring supplied must make a
perfect pressure seal. To achieve
secure mounting, use the proper
HB: 30-1mm
WB: 2"-0.04"
Nom. length =
stroke
Magnet
Thread size
HB: M18×1.5
25
Ø 5
WB: 3/4"-16UNF
A (1 : 1)
HB: 30-1mm
WB: 2"-0.04"
Nom. length =
stroke
Magnet
Thread size
HB: M18×1.5
WB: 3/4"-16UNF
25
A (1 : 1)
0.5 / Ø 25
nut for the mounting thread. When
tightening the nut, do not exceed a
tightening torque of 100 Nm.
For horizontal mounting of trans-
ducer with stroke lengths greater
than 500 mm, the pressure tube
should be supported or attached
at its end. When installing in a
hydraulic cylinder, do not allow the
magnet ring to rub against the
pressure tube. The bore diameter
Damping zone
60
Blind hole
M4×4/
6 deep
Mounting surface
0.5 / Ø 25
Damping zone
60
Blind hole
M4×4/
6 deep
Mounting surface
Ø 60
45
unusable area
not included
45
in the piston and cylinder rod
should be at least 13 mm.