CHARGE MODE CONFIGURATION DEPENDING
CHARGE
gel/AGM
CHARGE
gel/AGM
SELECT
CHARGE
CHARGE
Start up :
• Connect the clamps : red to the (+) and
black to the (-) of the battery.
• Push the START/STOP key to start
charging, a loading bar displays.
• Push the START/STOP key again to stop
the charge.
NB: When the charge ends (100%), if the battery remains connected the charger maintains the charge level of the battery by
applying a floating voltage.
Precaution: Check the electrolyte level and fill if necessary before charging.
DIAG MODE AND DIAG+ MODE
On a stationary vehicle the GYSFLASH supplies up to 50A to test high-energy consumers: engine fan, window regulator, electronic
suspension, etc... By supplying a steady voltage:
DIAG FUNCTION
- 13.5V (for every GYSFLASH model)
DIAG+ FUNCTION
- 12V to 14.8V (for 12V battery)
- 24V to 29.6V (for 24V battery, adjustable only on the GYSFLASH 50-24 HF)
- 6V to 7.4V (for 6V battery, adjustable only on the GYSFLASH 50-24 HF)
Voltage adjustment (only in Diag+ mode)
After selected the battery voltage (6V/12V/24V for the GYSFLASH 50-24 HF) it is possible to adjust the voltage by 0.1V step according
to manufacturer's specifications.
12
GYSFLASH 50-12 HF / 50-24 HF
ON THE BATTERY TYPE
12V
80Ah
3 sec
SELECT
12V
80Ah
SELECT
12V
gel/AGM
80Ah
SELECT
12V
80Ah
gel/AGM
6 V
12 V
24 V
easy
gel/AGM
liquid
expert
10Ah
20Ah
...
600Ah
CHARGE MODE START UP
CHARGE
12V
80Ah
gel/AGM
6V and 24V available only for the Gysflash
50-24 HF.
Charging curves available if activated in
EXPERT configuration.
Only for liquid, gel/AGM and expert
charging curves.
CHARGE
START
STOP
gel/AGM
EN
XX%
80Ah
SEL