POWER SUPPLY MODE (OPTIONAL)
This mode is intended for expert users only. This mode enables the charger to be used as a stabilised power supply, with regulated
voltage and adjustable maximum current. By default this mode is inactive and doesn't appear in the mode list. It can be activated via
the Expert configuration menu (see page 17).
POWER SUPPLY
Adjustment of the voltage regulation and current limitation :
U=19.6V
I<50A
The voltage regulation can be adjusted from 2V to 30V and the maximum current from 2A to 50A :
POWER SUPPLY MODE CONFIGURATION
POWER SUPPLY
U=13.5V
I<50A
3 sec
SELECT
POWER SUPPLY
SELECT
U=19.6V
I<50A
SELECT
POWER SUPPLY
U=19.6V
I<35A
NOTE: Unlike other modes, Power Supply mode, the charger does not compensate voltage drop in the cables. In this case, the vol-
tage displayed on the screen corresponds to the output voltage of the charger (not the voltage on the clamps).
CONFIGURATION MENU
Access to configuration menu :
To browse in the sub menu press the
«Select» key :
Sub menu :
• Languages :
This menu enables to language selection (use the arrows to change the
language).
• Automatic restart :
Automatic restart only works with «Showroom» Mode and «Charge»
Mode. This feature enables charger to restart automatically and to restart
charging after a cut in power. This feature is set as default => Display
«Configuration | Restart : ON».
• Lock Showroom :
To lock the device in Showroom Mode (to avoid misuse)
GYSFLASH 50-12 HF / 50-24 HF
POWER SUPPLY
START
STOP
U=19.6V
I=10A
2.0 V
2.1 V
...
30.0V
2A
3A
...
50A
3 sec - Mode
MODE
languages > restart > lock showroom > cable calibration > Expert
SELECT
Settings > Reset Memory
With battery connected :
• Push the START/STOP key to start the mode.
• During use, the current consumed and the instan-
taneous voltage are displayed.
POWER SUPPLY START UP
POWER SUPPLY
U=19.6V
I<50A
POWER SUPPLY
U=13.5V
I<50A
3 sec
SELECT
POWER SUPPLY
SELECT
U=19.6V
I<50A
SELECT

CONFIGURATION MODE

POWER SUPPLY
SETTINGS
U=19.6V
I<35A
English
SELECT
SETTINGS
restart:
SELECT
SETTINGS
lock showroom:
SELECT
SELECT
SETTINGS
Cables Testing:
Press START
to enter
SELECT
SETTINGS
Expert Settings:
Press START
to enter
SELECT
SETTINGS
Reset Memory:
Press START
to enter
EN
POWER SUPPLY
START
STOP
U=19.6V
I=10A
2.0 V
2.1 V
...
30.0V
2A
English
3A
Français
Deutsch
...
Nederlands
Espanol
50A
Portugues
Italiano
Russian
ON
ON
OFF
Y (yes)
N
N (no)
START
Test Cables
STOP
Expert
START
Settings
STOP
Reset
START
Memory
STOP
15