MAINTENANCE OF THE OLEODYNAMIC POWER UNIT
5
1
3
1
2
4
Periodically it is necessary to control the level of oil in the oleodynamic power unit which
directs the lifting operations, to execute this operation operate as follows :
1) lower the forks at the minimum possible height
2) disconnect the battery (1);
3) unscrew the screws (2 and 4) to remove the rear cover (3).
4) remove the cap (5) and control the level of the oil in the tank which must not be under 2
cm respect to the cap; if necessary execute the filling up with oil for electro-dynamic
circuits with a viscosity ISO VG46 with the help of a long funnel.
5) screw again with care the cap of the tank, pay attention to not contaminate the oil with
impurity.
6) Reassemble again the rear cover.
49