Maintenance Of The Oleodynamic Power Unit - Pegasolift PL13 Guía De Uso Y Mantenimiento

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

MAINTENANCE OF THE OLEODYNAMIC POWER UNIT

2
Periodically it is necessary to control the level of oil in the oleodynamic power unit which
directs the lifting operations of the lifting group, to execute this operation operate as
follows :
1) lower the lifting group at the minimum possible height
2) disconnect the start switch (reference page 16 "Tiller head" no.6) and the switch for
disconnecting the battery (reference page 16 "Instruments" no. 1)
3) unscrew the screws (part 2) and remove the rear cover (part 3).
4) control the level of the oil in the tank of transparent plastic (part 2); if necessary
unscrew the cork (part 3) and execute the filling up with oil for electro-dynamic circuits
with a viscosity ISO VG46 with the help of a long funnel.
5) screw again with care the cork of the tank, pay attention don't contaminate the oil with
impurity
6) assemble again the rear cover.
1
2
1
2
3
EMERGENCY DESCENT OF THE FORK GROUP
In case of an electric failure with the load lifted, operate as
follows to force the descent of the forks:
1) Remove the rear cover (part 3 figure A).
2) Unscrew the protection cap (part 1) and open the emergency
valve (part 2) until the lifting group begins to descent.
3) Wait until the load arrives at the minimum possible height.
4) Close with care the emergency valve (part 2) and screw again
the protection cap.
5) Assemble again the rear cover.