SYMBOL DEFINITIONS
No Smoking
Keep away from open
flame
Catalog Number
REPLACEMENT
The OXYMIZER Pendant device should be replaced
after approximately three weeks. More frequent
replacement may be needed for cleanliness and
sanitation, depending on conditions of use.
TODAY'S DATE:
Contact your healthcare provider or the manufacturer
to report unexpected operation or events.
SUPPLEMENTAL HUMIDIFICATION
Supplemental humidification is frequently
recommended for use with a nasal cannula. This is
typically accomplished by placing an appropriate
oxygen humidifier between the oxygen source and
the cannula. Since the OXYMIZER cannula uses
significantly less flow of oxygen than standard nasal
cannulas, the need for supplemental humidification
may be reduced or eliminated. Follow your
healthcare professional's recommendations
regarding the use of humidifiers.
CLEANING
The disposable OXYMIZER oxygen-conserving
devices are clean and ready to use, and are supplied
in individual containers. The outer surface may be
cleaned as needed with soap and water, but care
must be taken not to allow the membrane within the
reservoir to become wet.
P-224
FOR USE IN OXYGEN THERAPY
DISPOSABLE-FOR SINGLE PATIENT USE ONLY.
INSTRUCTIONS FOR USE ENCLOSED
CONTENTS: One (1) OXYMIZER Pendant
disposable oxygen-conserving device with curved
tubular nasal prongs, six (6) feet of connecting tube,
a female connector and user's manual.
REPLACE ON:
2797
Keep Dry
Prescription Only
Lot Number
INTENDED USE
The device is intended to be used as part of a
portable or stationary oxygen system for patients that
require supplemental oxygen in their home and for
ambulatory use.
CONTRAINDICATIONS
Not for use by infants and small children
Not for use by patients with nasal blockage
Not for use by patients with facial injuries that
would preclude the use of a cannula
Not for use by patients who will not leave the
nasal cannula in place
Not intended for multiple patient use
Not for use with pulse dose oxygen delivery
systems
DISPOSAL
Disposal for your device should be done in
accordance with local regulations.
SPECIFICATIONS
Max. Inlet Pressure
Max. Flow (LPM)
Operational Temp.
Operational Humidity
Storage Temp.
Storage Humidity
Expected Service Life is 21 days.
WARNING: To avoid strangulation keep tubing
away from children, pets, and closely supervise
impaired persons. Do NOT route tubing around
neck.
MANUFACTURED FOR:
Drive DeVilbiss Healthcare • 99 Seaview Boulevard
Toll-free: 877-224-0946 • www.drivemedical.com
© 2021 Inovo, Inc. Made in China PM-00053/21/H
ENGLISH
European
Representative
CE Marking of
Conformity
2797
Manufacturer
345 kPa (3.45 bar, 50 psi)
15 LPM
5°C to 40°C (41°F to 104°F)
15% to 93% non-condensing
-25°C to 70°C (-13°F to 158°F)
<= 93% non-condensing
Port Washington, NY 11050 • USA
Inovo, Inc • 401 Leonard Blvd. North
Lehigh Acres, FL 33971 • USA
MDSS GmbH • Schiffgraben 41
30175 Hanover, Germany
(01)00822383274508