2.3 UAT-600-RE Receiver Alerts

Screen Alerts
These alerts appear to the right-hand side of the screen and can appear at any time.
Indicates that the unit is not calibrated.
This is usually a factory setting. Service
should be contacted.
Service
Indicates less than 10% battery
remaining.
Battery low
Indicates that the signal is too large to
process correctly. No damage will occur to the
electronics, but measurements will be affected.
Signal
This condition is very unusual.
overload
When this icon appears the battery voltage
is so low that it is not possible to operate
Battery very
the locator. Replace or recharge batteries to
low
continue.
Depth Measurement Related Alerts
These alerts are associated with depth measurements and only appear within the depth pop-up screen section.
Depth Related Alerts
Signal Abnormal
Overhead Signal
Shallow Utility
8kHz
33kHz
50Hz
Radio
Not possible to compute depth because the signal is too noisy,
too weak or too strong.
Not possible to compute depth because of a strong signal
radiating from above (i.e., an overhead cable).
The unit has detected a shallow utility (less than 10 cm).
Caution is required when excavating.
8
457
501