Maintenance - Parker Chelsea URP50 El Manual Del Propietario

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Bulletin HY25-1793-M1/US
Power Take-Off Maintenance
Power Take-Off Maintenance
Due to the normal and sometime severe torsional vibrations that Power Take-
Off units experience, operators should follow a set maintenance schedule
for inspections. Failure to service loose bolts or Power Take-Off leaks could
result in potential auxiliary Power-Take-Off or transmission damage.
Periodic P.T.O. MAINTENANCE is required by the owner/operator to ensure
proper, safe and trouble free operation.
Daily:
Check all air, hydraulic and working mechanisms before operating
P.T.O. Perform maintenance as required.
Monthly: Inspect for possible leaks and tighten all air, hydraulic and
mounting hardware, if necessary. Torque all bolts, nuts, etc. to
Chelsea specifications. Ensure that splines are properly
lubricated, if applicable. Perform maintenance as required.
With regards to the direct mounted pump splines, the P.T.O. requires the
application of a specially formulated anti-fretting, high pressure, high
temperature grease. The addition of the grease has been proven to reduce
the effects of the torsional vibrations, which result in fretting corrosion on the
P.T.O. internal splines as well as the pump external splines. Fretting corrosion
appears as a "rusting and wearing" of the pump shaft splines. Severe duty
applications, which require long P.T.O. running times and high torque may
require more frequent regreasing. Applications such as Utility Trucks that run
continuously and are lightly loaded also require frequent regreasing due to
the sheer hours of running time. It is important to note that service intervals
will vary for each and every application and is the responsibility of the end
user of the product. Chelsea also recommends that you consult your pump
owners manuals and technical services for their maintenance guidelines.
Fretting corrosion is caused by many factors and without proper
maintenance; the anti-fretting grease can only reduce its effects on
components.
Chelsea offers the grease to our customers in two packages. The first is a
5/8 fluid ounce tube (379688), which is included with every applicable P.T.O.,
and the second is a 14-ounce grease cartridge (379831). Chelsea also
offers greaseable shafts for most all output designators.
Warranty: Failure to comply entirely with the provisions set forth in
the appropriate Owner's Manual will result in voiding of ALL
Warranty consideration.
Owner's Manual
URP50 Tank
10
Parker Hannifin Corporation
Chelsea Products Division
Olive Branch, MS 38654 USA

Publicidad

Capítulos

Tabla de contenido
loading

Tabla de contenido